DEB Unvented Gas Logs
Label all wires prior to disconnection when
servicing controls.
Wiring errors can cause improper and dan-
gerous operation.
Verify proper operation after servicing.
Wall
Switch
On/Off Switch
Figure 17 -
Wiring Diagram
The millivolt valve is a self-powered combination gas control
THAT DOES NOT REQUIRE 110 VAC TO OPERATE.
CONNECT OPTIONAL WALL SWITCH OR
THERMOSTAT
1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall
switch or thermostat. At the other end, connect one
wire to TP/TH and one wire to TH, or connect the wall
switch/thermostat to the two male (0.25") terminals on
the left side of the unit. The color of the wires does not
matter.
14
TH = 3
TP = 1
TP/TH = 2
Switch

ELECTRICAL WIRING - MILLIVOLT

On/Off
Switch
ODS Pilot
Millivolt
Valve
Spade Terminal
Optional Wall
Switch, Remote
Receiver or
Optional T-Stat
FP2112
wiring diagram
12/08
ODS Pilot
FP2112
44D0060