Replace with the appropriate pilot orifice.
#51 for natural gas
#30 for propane
Be certain the orifice is securely tightened.
Replace the Pilot Hood into the base.
12. Replace the Variable Regulator: Using a Torx T-
20 screwdriver, remove the three specialty screws
from the front of the valve regulator. See Fig. 14.
13. Remove the regulator tower and the old black
gasket.
14. Ensure that the new gasket is properly posi-
tioned and install the new variable regulator
tower. Tighten screws securely. Apply the small
valve label to the valve body where it will be
easily seen.
15. Reinstall the Burner Tube (13, pg. 22), Air Divider
(15), Log Support (14), and Log Set. WHEN
REINSTALLING THE BURNER TUBE, BE SURE THE
TUBE IS PULLED FORWARD IN THE MOUNTING
HOLES. SECURE WITH THE TWO 1/4" SCREWS.
16. Apply the two conversion labels to the stove
and rating plate so that they can be seen by
anyone servicing the stove.
17. Reassemble the stove, open the gas supply and
check for leaks using a 50/50 soapy water
solution. NEVER USE AN OPEN FLAME TO CHECK
FOR GAS LEAKS.
Pilot Hood
Pilot Orifice
Figure 13. Removing the Pilot Hood and Pilot Orifice.
Pilot Base
Figure 14. Regulator tower and gasket.
Correct gas pressure is essential for efficient and
safe operation of the Allagash gas stove. It is
important that the correct gas pressure be estab-
lished at the time of the installation. For more
details see the Gas Pressure section of this manual.
ALWAYS REFER TO THE LIGHTING
INSTRUCTIONS ON THE INSIDE BACK
COVER OF THIS MANUAL AND ON THE
BACK OF THE RATING PLATE.
Screws
Regulator Tower
Gasket