Optional Blower Installation - Jøtul Allagash GF3 DVII Installation And Operation Instructions Manual

Direct vent gas heater
Table of Contents

Advertisement

Optional Blower Installation

IMPORTANT: IF THE OPTIONAL
FORCED BLOWER KIT(PART # 129161)
IS TO BE INSTALLED ON THE STOVE
AT THE TIME OF THE INSTALLATION
OR IN THE FUTURE, THE GAS SUPPLY
LINE SHOULD BE INSTALLED AS
CLOSE TO THE FLOOR AS POSSIBLE.
USE OF A 90° DIRECTLY OFF THE
VALVE WILL ALLOW FOR PROPER
CLEARANCE FOR THE BLOWER. SEE
FIG. 18.
Blower Kit Contents:
• Blower with mounting bracket
• Snapstat and Wiring Harness
• Hi/Low/Off Switch
• two 6mm bolts
Attach the Blower
1. Locate the two raised bosses on the bottom back
of the stove. See Figure 19. The blower is
mounted to the stove using these two threaded
holes.
2. With the blower bracket and snapstat facing
upward, align the two middle mounting holes
on the bracket with the two threaded holes on
the bottom back of the stove.
3. Use the two 6mm bolts to attach the blower to
the stove. Be sure to tighten the bolts so that
the blower is drawn upward and tight against
the stove bottom.
4. The snapstat (thermodisc), attached to the
blower bracket, should be inserted under the
stove bottom to make contact with the firebox!
Connect the Blower Wiring Harness
1. Lift off the stove top plate.
2. Loosen (
BUT DO NOT REMOVE
the switch box to the side of the stove (left rear
corner of the stove), and lift out the switch box.
3. Remove the "blank" switch from the box. (Hint:
break the retaining tabs holding the switch in the
box.)
4. Insert the new HI/OFF/LO switch into the box.
5. Connect the insulated wires from the blower to
three leads on the HI/OFF/LO switch. BLACK wire
to the HI position, WHITE wire to the OFF position,
and the RED wire to the LO position. See Fig. 22.
6. Reattach the switch box to the side of the stove.
Be sure all wires are unobstructed.
7. Replace top plate.
) the 10 mm bolt holding
Blower
Gas Line
Figure 19. Blower and gas line installation.
Figure 20. Blower attachment points.
Figure 21. Blower position installed.
The blower will ONLY come on when the switch is in
the Hi or Low position and ONLY when the snapstat
(thermodisc) is heated by the operation of the stove.
(Approximately 10- 20 minutes after the stove has
been running).
90° elbow installed
directly off valve to
avoid blower
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents