Rinnai RCE-460PTR Service Manual page 34

Fan convector
Table of Contents

Advertisement


(
3520 'DWD
2
E
PROM data will not be erased during a power failure. However, this data is divided into 2 groups
where one of the groups of data can be reset at the external control pads.
[Permanent Data]
• Modulating Valve Current Supplement
Value
• Fan Current Supplement Value
• Estimated Combustion Time
• Combustion Frequency
• Estimated Air Purifier Operation Time
<Resetting>
Refer to "How to Reset" under "Memory Function for Maintenance Data".
<Test Mode and Adjustable Mode>
There is a Test Switch on the PCB.
If it is changed over to gas conversion mode while the unit is OFF and with the test button ON, the
present gas type code will be displayed.
The gas type code will change with the " ∧ " and " ∨ " temperature buttons.
a. When the " ∨ " button is pressed
"13" (NG)
b. When the " ∧ " button is pressed.
"LP"
The gas type code will be stored in memory if the test button is pressed again.
Convector 460/560PTR
[Deletable Data]
• Present Time
• Error History
• Timer 1 Time
• Timer 2 Time
• Set Room Temperature
• Air
Normal OFF
"LP"
"13" (NG)
- 29 -
Purifier
Operation
Time
Test Switch
Gas Conversion
Mode
(Initial Setting)
( 0:00 AM)
(None)
( 6:00 AM)
( 6:00PM)
( 22 C)
°
( 0 Hours)
©Rinnai