THIS MANUAL MUST BE READ IN ITS
ENTIRETY BEFORE OPERATING HEATER
VENT-FREE GAS CONVECTION HEATER
With Plasmacluster
Owner's Operation and lnstallation Manual
THIS IS AN UNVENTED GAS-FIRED HEATER. IT USES AIR (OXYGEN)
FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR
ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED.
REFER TO INSTALLATION INSTRUCTIONS ON PAGE 6.
WARNING:
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE
IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S
PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
INSTALLER:Leave this manual with the appliance.
CONSUMER:Retain this manual for future reference.
HOME OWNER / INSTALLER
FOR YOUR SAFETY
RCE-592ACPA
+HEPA AIR CLEANING TECHNOLOGY
TM
FC-420 HEPA
WHAT TO DO IF YOU SMELL GAS
+
CORPORATION
NAGOYA, JAPAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RCE-592ACPA and is the answer not in the manual?

Questions and answers

Summary of Contents for Rinnai RCE-592ACPA

  • Page 1 HOME OWNER / INSTALLER FOR YOUR SAFETY THIS MANUAL MUST BE READ IN ITS ENTIRETY BEFORE OPERATING HEATER RCE-592ACPA VENT-FREE GAS CONVECTION HEATER With Plasmacluster +HEPA AIR CLEANING TECHNOLOGY FC-420 HEPA Owner's Operation and lnstallation Manual THIS IS AN UNVENTED GAS-FIRED HEATER. IT USES AIR (OXYGEN) FROM THE ROOM IN WHICH IT IS INSTALLED.
  • Page 2: Table Of Contents

    WARNING THIS APPLIANCE IS INTENDED FOR SUPPLEMENTAL HEATING. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVlCE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
  • Page 3: Specifications

    Input Rating Input Rating Thermostat Weight Dimension Fan CFM BTU/H HIGH BTU/H LOW in pounds in inches Output RCE-592ACPA-N 20,000 4,000 Height: 26 3/10" High:129 Width: 18 9/10" RCE-592ACPA-P 18,000 6,000 Depth: 11 4/10" Low:82 "-N" Models are for Natural Gas. (Inlet Pressure within 5.9"-10.5" W.C.) "-N"...
  • Page 4: Important Points

    IMPORTANT POINTS UNPACK HEATER: Check for damage. (DO NOT INSTALL DAMAGED HEATER.) If heater is damaged, contact your supplier for advice. Before installing a heater, check the label for the correct gas type (see label on back of heater). Refer to local gas authority for confirmation of gas type if you are in doubt. INCLUDED IN CARTON: Customers Operating Information/Manual Gas Valve IMPORTANT...
  • Page 5: Safety Points

    SAFETY POINTS Do not install this heater in areas where Do not move the heater while it is turned on. spray painting or plating is taking place, or in places such as hair dressers, where there may be a lot of fluff and dust, and where aerosols are used.
  • Page 6 SAFETY POINTS Do not place wet articles on this heater, the Do not allow children to put articles in the water may drip into the electrical parts. louvers. Supervise children playing near this heater. Do not turn the heater off by unplugging it Ventilate the room when this heater is in from the wall, or while the fan is cooling the use.
  • Page 7: Usage And Installation Information

    USAGE AND INSTALLATION INFORMATION 1. Read these rules and the instructions carefully. Check all local codes. Failure to follow these could cause a malfunction of the heater resulting in death, serious bodily injury and/or property damage. 2. This heater is designed for use only with one type of gas, either L.P.G. or Natural Gas. Make sure that the type of gas to be supplied to this unit matches that shown on the rating plate on the heater.
  • Page 8: Installation Instructions

    INSTALLATION INSTRUCTIONS NOTICE BEFORE INSTALLATION The heater must be installed by a qualified service person according to these installation instructions. When used without adequate combustion and ventilation heater air the heater may give off carbon monoxide. Check your local building codes for the proper method of installation. In the absence of local codes, this heater installation must conform with American National Standard (National Fuel Gas Code) ANSI Z223.
  • Page 9 Unusually tight construction is defined as construction where: a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6×10 kg per pa-sec-m ) or less with openings gasketed or sealed, and b) Weather stripping has been added on openable windows and doors, and c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing,...
  • Page 10 5. Any compound used on the threaded joint of gas piping shall be a type which resists the action of liquefied petroleum gas. 6. Supplied gas pressure must be within the limits shown in the specifications. 7. After completion of gas pipe connections, all joints including the heater must be checked for gas- tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution, as applicable.
  • Page 11: Operating Instruction Plate

    OPERATING INSTRUCTION PLATE CONVECTOR RCE-592ACPA FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. · A. This appliance does not have a pilot. It is equipped...
  • Page 12: Control Panel Operating Information

    CONTROL PANEL OPERATING INFORMATION INSTALLATION Check room size and ventilation. Do not Make certain the heater is connected into both oversize. Improper sizing may cause nuisance the gas and the electric power. lock outs. CONTROL PANEL LAYOUT - 10 -...
  • Page 13: Replacing The Hepa Filter

    REPLACING THE HEPA FILTER 1. To remove the HEPA filter · Remove the screw using Philips head. · Remove the Filter Screen and the HEPA Filter. SCREW 1 OPEN 2 PULL 2. To install the HEPA filter · Remove the HEPA Filter from bag and place into the Filter Screen.
  • Page 14: Operating The Heater

    OPERATING THE HEATER TURNING ON  Press the ON/OFF button to operate the heater. The ON indicator will glow green. After approximately 20 seconds the spark generator will be heard before the burner ignites and the ON indicator glows red, indicating that the burner is lit.
  • Page 15 OPERATING THE HEATER ECONOMY MODE The Economy mode may only be operated when the heater is turned on, and remains in the system memory once set until deactivated. Press the Economy button to start Press the Economy button once more the Economy function.The Economy to switch off the function.
  • Page 16: Timer Operation

    TIMER OPERATION OFF TIMER OPERATION  This feature is useful on cold nights when the unit continues to operate after you have gone to bed. The OFF Timer can be selected when the heater is operating manually, in OFF, or in ON Timer mode. When the OFF Timer feature is selected, the heater will automatically switch off after 60 minutes.
  • Page 17 WARNING · Ensure there are no obstacles or foreign materials directly in front of the appliance where the warm air will discharge into the room. · Ensure the appliance is not positioned where warm air discharge will blow directly on someone sleeping.
  • Page 18 Air purifier with Plasmacluster Ion Operation  1 Press Air Purifier with Ion button. · When "H" is selected, the unit will continually clean air at the air at the highest fan speed. During this operation, the same number of positive and negative ions are discharged.
  • Page 19: Maintenance / Service

    MAINTENANCE / SERVICE MAINTENANCE SUGGESTIONS This heater has been designed and constructed for a long performance life when installed and operated properly under normal conditions. Regular inspections, as outlined in this section, are strongly recommended as means of keeping your heater operating efficiently and throughout the season. Access to internal parts is from the front of the heater.
  • Page 20 Button except after replacing with a new HEPA filter. Note: If the consumer has trouble finding the replacement HEPA filters at the dealer where they bought the unit, they could contact us directly at our web site. ( www.rinnai.us ) - 18 -...
  • Page 21 Clean air filter at least once a week. Do not wait for filter warning lamp to come on before cleaning filter. Do not use the heater with the filter warning lamp on, this may cause it to overheat. A dusty filter reduces the air fIow through the heater, as well as, reducing the heater's effectiveness.
  • Page 22: Trouble Shooting Chart

    TROUBLE SHOOTING CHART Please note: General cleaning, maintenance and wear and tear are not necessarily covered under the guarantee. CaIIs of this nature may be chargeable. Problem Remedy Cause Not Plugged In Plug In Re-ignite manually after Power OFF power is restored (Initial Installation) Purge air (installer) Air in gas pipe...
  • Page 23 - 21 -...
  • Page 24: Schematic Disassembly

    - 22 -...
  • Page 25 - 23 -...
  • Page 26 - 24 -...
  • Page 27 - 25 -...
  • Page 28 - 26 -...
  • Page 29 PART NAME PART No. QTY. REMARKS PART NAME PART No. QTY. REMARKS FRONT PANEL RC-592-20-1 THERMOCOUPLE FIXER RC-210-89-2 LOUVER ASS’Y RC-592-25-1 CONVECTION FAN RC-592-17 REAR PANEL RC-592-21-2 CASING ASS’Y RC-511-28 TC CHECK HOLDER RC-334-73-1 MOTOR BRACKET RC-513-215 THERMISTOR COVER RC-353-233 BEARING BRACKET RC-504-32 HANDLE...
  • Page 30: Error Messages

    Turn heater OFF, Power cut then ON again. If you see other codes displayed, contact Rinnai or your nearest service agent and arrange for a service call. In all cases, you may be able to clear the Error Message simply by turning the heater OFF, then ON again.
  • Page 31 - 29 -...
  • Page 32: Limited Warranty

    Any such warranty replacement or repair shall be subject to the terms and conditions of this warranty for the remainder of the original period of coverage. In order to obtain the name and location of the qualified Rinnai servicing agent closest to you, please write Rinnai at the address shown on the warranty card or call Rinnai at 1-800-621-9419.