Sensor Specification
Ignition Sensing
Voltage (mV)
Output at initial
check +2
"Drop Out" = Time until the gas is cut off after flame failure.
Sensing voltage varies depending on gas type. (Refer to combustion specifications)
Overheat Switches
If the air filter or air outlet becomes blocked, the overheat switch causes the solenoid valve to close
and operation to stop. The appliance can be re-lit when it has cooled. If the air filter or outlet
becomes blocked and the OHS fails, the thermal fuse will "blow", causing the solenoid valve to close
and operation to stop. This is a "one-shot" fuse; therefore the appliance cannot be restarted until this
fuse has been replaced.
OHS Type
Thermistor
Thermal Fuse
Reverse Flame Detection Device
Type
Reserve Flame
Detection Switch
(Bi-metal)
Tilt Switch Safety Device
Normally, the tilt circuit is open, but the steel ball rolls when the unit is tilted, closing the circuit.
Steel Ball Tilt Switch
Convector 460/560PTR
ODS Sensing Voltage
(mV)
NG: level 4~12
±
14
1.5
±
level 1~3 14
1.5
LPG: level 4~12
±
16
1.5
level 1~3 16
±
1.5
Characteristics
level 4~12
1~3
Cut Off Temp
Characteristics
Operational
Temp.
Reset Temp.
Activating Angle
Thermocouple Output
NG: >18mV
LPG: >20mV
NG: >18mV
LPG: >20mV
Operates at
70 C
°
±
0
°
216
C
10
±
C
°
150
5
±
125
10
°
C
° ~ 80°
50
- 20 -
Drop Out
Time (sec)
<35mV
Below 60
<35mV
OFF
ON
©Rinnai