3.4.6
When used in this mode, the air conditioner only

Dehumidifier only

eliminates the humidity in the room, practically without
changing the temperature. This function can be extremely
useful between seasons, particularly on rainy days when
the temperature is not uncomfortable but the excess
humidity feels unpleasant.
When used in this mode, the air conditioner ignores the
temperature and fan speed settings, which are not shown
on the display in this case.
To operate the air conditioner in this mode, press Button
T4 until the droplet symbol appears on the display with
automatic ventilation.
In this operating mode it is normal for the air conditioner to
function intermittently.
3.4.7
When used in the mode the air conditioner does not act on the
either the temperature or the humidity in the room, but only

Fan Only

keeps the air in circulation. This operating mode is
selected by pressing button T4 until the fan symbol
appears on the display. At this stage you can select the
fan speed (see paragraph 3.4.10).
3.4.8
When used in this mode the air conditioner heats the
Heating function
room. This function is only available on models with a
(only models with
heating pump (HP).
heat pump)
To select this mode press button T4 (operating mode
selection switch) until the sun symbol appears on the
display. First set the desired temperature and fan speed (see
the specific paragraphs). After three minutes (maximum
time) the compressor should start and the air conditioner starts
heating the room. When the compressor starts you will see a
green LED light up on the control panel.
Note: The air conditioner has to defrost its battery
periodically (about once every half hour). During this
operation (about 3-8 minutes) the air conditioner does
not heat the room, though its internal parts remain on
except for the room air fan.
temperature is very low, there may be a slight delay
(about 3 minutes) for passage from the minimum to the
medium or maximum speed from when the command is
sent to the machine with the remote control.
3.4.9
The airflow can be controlled in both its horizontal and
Control of air flow
vertical direction. Control of the horizontal direction cannot
Direction
be carried out with the remote control and must be made
manually by adjusting the position of the fins on the outlet
opening.
IMPORTANT: Adjustment of horizontal airflow should only
be made when the movable grille is not moving.
When the outdoor
Fig. 32
Fan only
Fig. 33

Heating function (only models with heat pump)

Fig. 34

Control of air flow direction