Convection Blower Replacement - Quadra-Fire MTVERNON-AE-MBK Owner's Manual & Installation

Mt. vernon pellet stove advanced energy
Hide thumbs Also See for MTVERNON-AE-MBK:
Table of Contents

Advertisement

R
E. Convection Blower Replacement
1. Follow the proper shut down procedures as outlined on
page 25, Section 10A.
2. Remove the left side panel by removing the 4 screws
using a Phillips head screw driver. Figure 29.1.
3. Depress the tab on the left side and snap out the power
supply. You do not need to disconnect any wires.
4. Remove the 2 screws at the bottom of the back panel
so there will be room to remove the blower.
5. Reach behind the blower and pull out the detent pin.
Figure 29.2.
6. Rock the top of the blower slightly and lift up. The
blower will pass around the control board and out the
left side of the appliance.
7. Disconnect the wire harness from the bottom of the
blower by depressing the tabs on the sides of the con-
nector and then pulling to remove.
8. Install replacement blower by placing the bottom fl ange
into the opening fi rst then rotate blower up into position.
Figure 29.2.
9. While holding the blower in place, reach over the blower
and insert the detent pin through the 2 holes. You may
fi nd it easier to remove the right side panel and insert
the detent pin from the right side as opposed to the left
side. Figure 29.3.
10. Re-secure the back panel, snap the power supply back
in and re-secure the side panel(s).
Remove 2
Screws
Detent Pin
Figure 29.1
December 22, 2006
Depress Tab and
Snap Out Power
Supply
Remove
Side
Panel
Disconnect Wire Harness
from Bottom of Blower
7034-106B
Mt. Vernon Pellet Stove (AE)
Place bottom of
flange in opening first
Figure 29.2
Detent Pin Installed
Figure 29.3
Detent Pin Brackets
Page 29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mtvernon-ae-pmhMtvernon-ae-csbMtvernon-ae-cwl

Table of Contents