Maintenance
Remove Battery
1. Remove the left side cover.
2. Remove the battery hold- -down strap.
3. Disconnect the negative ( - - ) battery cables (exposed connectors).
4. Disconnect the positive ( + ) cables (covered with a red boot).
Caution
Disconnecting the positive cable first can produce an electric shock that could result in damage or injury.
5. Slide the battery out.
The multi- -function display (MFD) clock will not function if the battery voltage drops below 11.5
Notice
volts. The clock will reset to 12:00 if the battery is disconnected.
Charge Battery
WARNING
The battery may contain explosive gases.
• Keep sparks, cigarettes, or any flame away from the battery.
• Shield eyes and protect skin and clothing when handling or working near the battery.
• Make sure ventilation is adequate when charging or using the battery in an enclosed space.
• During charging, if the battery gets very hot to the touch, stop charging and let the battery cool
down before continuing.
106