Definition of cosmetic specifications
Hot/Dead pixel defect:
Pixel whose signal, in dark, deviates by more than 400DN (10-bits) from the mean.
Single pixel defect:
Pixel whose signal, at nominal light (illumination at 50% of the linear range), deviates by more than ±30% from
the mean.
Cluster defect:
A grouping of more than 8 pixel defects.
Column defect:
A column which has more than 8 consecutive pixel defects.
Row defect:
A horizontal grouping of more than 8 consecutive pixel defects.
Test conditions
Digital gain = 1X
Nominal light = illumination at 50% of saturation
Temperature of camera front plate is 40°C