connection box.
• As the appliance is not fitted with an accessible plug, a means of
disconnection from the power supply must be must be included in
the fixed insatllation, in accordance with the installation regulations.
• The inlet cable must be positioned so that it does not touch any of
the hot parts of the hob or oven.
Caution
• This appliance must only be connected to a 230V ~ 50Hz mains
electrical supply.
• The connection box is located underneath at the back of the hob
casing. To open the cover use a flat screwdriver. Insert it in the slits
to open the cover.
• Ensure that a bridge is fitted between terminals L1 and L2 and
another bridge between terminal N1 and N2.
Mains electrical voltage:
Total rated electrical consumption:
24
230Vac, 50 Hz
6.5 kW