Head System; Water System; Fuel Systems - Sea Ray 340 Sundancer Owner's Manual

Hide thumbs Also See for 340 Sundancer:
Table of Contents

Advertisement

S
ECTION
Keep under a trickle charge.
When placing battery back into service, remove
excess grease from terminals, recharge as
necessary and reinstall in boat.
D. H
S
EAD
YSTEM
Flush entire system thoroughly with fresh water.
Pump out holding tank.
Remove water line from inlet fitting located
on back bottom half of water valve on head.
Flush one gallon (four liters) antifreeze mixed
with one gallon (four liters) of water through toilet
and let vacuum pump run for one or two
minutes.
Shut WATER SYSTEM breaker OFF.
Pump out holding tank.
E. W
S
ATER
YSTEM
Turn ON the WATER SYSTEM switch.
Open water faucet, let system drain completely.
Turn OFF the WATER SYSTEM switch.
Water must be removed from the water lines
with air pressure or flushed with a nontoxic
antifreeze.
Using pressurized air to remove water from water
lines:
You must have an air compressor with air hose
and air nozzle.
Remove water hoses from water pump.
Alternate opening one faucet at a time to make
sure water is removed from each line.
8.6
8 • R
EQUIRED
M
AINTENANCE
I
, S
NSPECTION
Blow air through the water lines removed from
the water pump.
NOTE: When blowing air be careful not to blow air
with all faucets closed. System could be damaged
by overpressurization and create water leaks.
Cover hose ends with screen or broad weave
cloth and tape in place to keep out dirt and bugs.
U
N
W
SING
ONTOXIC
INTERIZING
Purchase a nontoxic winterizing antifreeze for
fresh water systems from a marine or RV supply
retailer.
With all water pumped out of the system add
nontoxic antifreeze to the water tank. Pour in
enough to be pumped to all faucets and
showers.
Close all faucets and turn on water system.
Open one faucet at a time. Close faucet when
nontoxic antifreeze comes out of faucet.
After all faucets and showers have been treated,
open all faucets and pump out remaining
nontoxic antifreeze.
W
H
W
ATER
EATER
Refer to your water heater Owner's Manual for
detailed information on preparing water heater
for storage and winterization.
F. F
S
UEL
YSTEMS
G
:
ASOLINE
Fill fuel tank with gasoline and the
recommended amount of stabilizer and
conditioner such as "Stabil
Run engine(s) for ten minutes to ensure that all
gasoline in the carburetor and fuel lines are