Programming Automatic Rearming:
Follow Steps 1 to 4 on page 20; at Step 4 the Valet Switch will be pressed and
released fifteen times. The system's response will be fifteen siren chirps, and
the Status Light flashing fifteen times, pausing, then repeating. Within 10
seconds, press and release the transmitter's Large Upper Button to turn on
the Automatic Rearming feature (
Button to turn the Automatic Rearming feature off (
Feature #16 Doors Lock With Automatic Rearm
(Factory Default Setting On)
This feature adds the automatic locking of the doors to the previous
feature, Automatic Rearming. If this feature is turned on, the doors will lock
when the system rearms itself 90 seconds after being disarmed by the
transmitter. Feature #15 must be turned on for this feature to operate.
Programming Doors Lock With Automatic Rearming:
Follow Steps 1 to 4 on page 20; at Step 4 the Valet Switch will be pressed
and released sixteen times. The system's response will be sixteen siren
chirps, and the Status Light flashing sixteen times, pausing, then repeating.
Within 10 seconds, press and release the transmitter's Large Upper Button
to turn this feature on (the siren will chirp once) or the Small Lower Button
to turn this feature off (the siren will chirp twice).
Feature #17
This feature determines how long after the Arming confirmation chirp
that the system becomes fully Armed. The Arming Delay applies to the
system Arming regardless if it occurs from using the transmitter, Last Door
Arming or Automatic Rearming.
Programming 3 / 45 Second Arming Delay:
Follow Steps 1 to 4 on page 20; at Step 4 the Valet Switch will be pressed
and released seventeen times. The system's response will be seventeen siren
chirps, and the Status Light flashing seventeen times, pausing, then repeat-
ing. Within 10 seconds, press and release the transmitter's Large Upper
Button to configure the system with a 3 second Arming Delay (the siren will
chirp once) or the Small Lower Button to configure the system with a 45
second Arming Delay (the siren will chirp twice).
the siren will chirp once
3 / 45 Second Arming Delay
(Factory Default Setting 3 Second)
Page 29
) or the Small Lower
the siren will chirp twice
).