OPERATING TIPS

AUTO Restart

In Event of Power Interruption
● The air conditioner power has been interrupted by a power
failure. The air conditioner will then restart automatically in
its previous mode when the power is restored.
● Operated by setting before the power failure.

Temperature and Humidity Range

Outdoor temperature
Indoor temperature
● If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to
prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than
those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
● Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
● If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip
onto the fl oor or other objects underneath. (About 80% or more).
● If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the
outdoor unit may stop operation for certain period of time.

SPECIFICATIONS

MODEL
INDOOR UNIT
OUTDOOR UNIT
TYPE
POWER
COOLING
CAPACITY
POWER INPUT
CURRENT (MAX.)
ENERGY EFFICIENCY RATIO
AIRFLOW
INDOOR UNIT
OUTDOOR UNIT
HEATING
CAPACITY
POWER INPUT
CURRENT (MAX.)
ENERGY EFFICIENCY RATIO
AIRFLOW
INDOOR UNIT
OUTDOOR UNIT
MAX. PRESSURE
REFRIGERANT (R410A)
DIMENSIONS & WEIGHT (NET)
INDOOR UNIT
HEIGHT
WIDTH
DEPTH
WEIGHT
OUTDOOR UNIT
HEIGHT
WIDTH
DEPTH
WEIGHT
Cooling Mode
About -10 to 46 °C
About 18 to 32 °C
ASBA24LFC
AOBR24LFL
[kW]
7.03
[BTU/h]
24,000
[kW]
2.16
[A]
9.9 (13.5)
[kW/kW]
3.26
[m
/h]
1,100
3
[m
/h]
2,470
3
[kW]
7.91
[BTU/h]
27,000
[kW]
2.31
[A]
10.6 (18.5)
[kW/kW]
3.42
[m
/h]
1,120
3
[m
3
/h]
2,570
[MPa]
4.12
[kg]
1.65
[mm]
[mm]
[mm]
[kg]
[mm]
578
[mm]
790
[mm]
315
[kg]
● If a power failure occurs during TIMER operation, the timer will
be reset and the unit will begin (or stop) operation at the new
time setting. In the event that this kind of timer fault occurs the
TIMER Indicator Lamp will fl ash (see Page. 4).
● Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the air
conditioner to malfunction. In this event, temporarily discon-
nect the Power Supply Plug, reconnect it, and then use the
Remote Controller to resume operation.
Dry Mode
About -10 to 46 °C
About 18 to 32 °C
HEAT & COOL SPLIT TYPE (REVERSE CYCLE)
220 V ~ 60 Hz
320
998
228
14
43
Heating Mode
About –15 to 24 °C
About 30 °C or less
ASBA30LFC
AOBR30LFT
7.91
27,000
2.44
11.2 (17.0)
3.24
1,100
3,600
9.08
31,000
2.77
12.7 (19.0)
3.28
1,150
3,600
4.12
2.10
830
900
330
61