Fujitsu INVERTER ASBA18JCC Operating Manual

Wall mounted type
Hide thumbs Also See for INVERTER ASBA18JCC:

Advertisement

AIR CONDITIONER
ACONDICIONADOR DE AIRE
AR CONDICIONADO
COOLING ONLY MODEL
MODELO SÓLO REFRIGERACIÓN
MODELO SÓ ARREFECIMENTO
Indoor unit
Unidad interior
Unidade interna
ASBA18JCC
ASBA24JCC
ASBA30JCC
Outdoor unit
Unidad exterior
Unidade externa
AOBR18JCC
AOBR24JCC
AOBR30JCT
A garantia contratual somente é válida para produtos
instalados por assistência técnica credenciada.
Keep this manual for future reference.
Conserve este manual para futura referencia.
Guarde este manual para futura referência.
FUJITSU GENERAL LIMITED
OPERATING MANUAL
MANUAL DE FUNCIONAMIENTO
MANUAL DE OPERAÇÃO
WALL MOUNTED TYPE
TIPO MONTADO EN PARED
TIPO MONTADO NA PAREDE
PART No. 9315161185-05

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu INVERTER ASBA18JCC

  • Page 1 AOBR18JCC AOBR24JCC AOBR30JCT A garantia contratual somente é válida para produtos instalados por assistência técnica credenciada. Keep this manual for future reference. Conserve este manual para futura referencia. Guarde este manual para futura referência. FUJITSU GENERAL LIMITED PART No. 9315161185-05...
  • Page 2 Fig. 1 MANUAL AUTO Fig. 2 OPERATION TIMER SUPER QUIET Fig. 3 Fig. 5 Fig. 4 AOBR18JCC AOBR30JCT AOBR24JCC Fig. 6 MODE START STOP TEMP. SLEEP SWING TIMER TIMER MODE Fig. 7 CLOCK TEST RESET ADJUST To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators;...
  • Page 3: Table Of Contents

    AIR CONDITIONER OPERATING MANUAL Indoor unit (Wall mounted type) PART No. 9315161185-05 CONTENTS SAFETY PRECAUTIONS ........En-1 MANUAL AUTO OPERATION .......En-8 FEATURES AND FUNCTIONS ......En-2 ADJUSTING THE DIRECTION OF NAME OF PARTS ..........En-3 AIR CIRCULATION ..........En-9 PREPARATION .............En-4 SWING OPERATION ..........En-10 OPERATION ............En-5 CLEANING AND CARE ........En-10 TIMER OPERATION ..........En-7...
  • Page 4: Features And Functions

    FEATURES AND FUNCTIONS INVERTER OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION) At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit Three-dimensional control over air direction swing is possible automatically switches to a low power setting for economic and through dual use of both an UP/DOWN air direction swing and comfortable operation.
  • Page 5: Name Of Parts

    NAME OF PARTS Fig. 6 Remote Control Unit Fig. 1 Indoor Unit J SLEEP button 1 Operating Control Panel (Fig. 2) K MODE button 2 MANUAL AUTO button L SET TEMP. button ( ● When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced M Signal Transmitter cooling operation will start.
  • Page 6: Preparation

    PREPARATION CAUTION Load Batteries (Size AAA R03/LR03  2) * ● Take care to prevent infants from acciden- tally swallowing batteries. Press and slide the battery compartment lid on the ● When not using the Remote Control Unit for reverse side to open it. an extended period, remove the batteries to avoid possible leakage and damage to the Slide in the direction of the arrow while pressing the...
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button (Fig.6 Q). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. Press the MODE button (Fig.6 K) to select the desired mode. Each time the button is pressed, the mode will change in the following order.
  • Page 8 OPERATION To Stop Operation Press the START/STOP button (Fig. 6 Q). The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation ● When AUTO CHANGEOVER operation fi rst selected, the fan will operate AUTO: at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (☞ P. 4). To Use the ON timer or OFF timer Press the START/STOP button (Fig. 6 Q) To Cancel the Timer (if the unit is already operating, proceed to step 2).
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP Timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER MODE button to select “CAN- SLEEP button (Fig.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION ● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit. ● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airfl ow-direction louvers have stopped moving. WARNING Vertical Air Direction Adjustment ●...
  • Page 12: Cleaning And Care

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button (Fig. 6 T). The SWING Display (Fig. 7 b) will light. Each time the SWING button is pressed, the swing operation will change in the following order.
  • Page 13: Cleaning The Intake Grille

    CLEANING AND CARE Cleaning the Intake Grille Cleaning the Air Filter 1. Remove the Intake Grille. 1. Open the Intake Grille, and remove the air 1 Place your fi ngers at both lower ends of the grille panel, fi lter. and lift forward;...
  • Page 14: Air Cleaning Filter Installation

    CLEANING AND CARE Air Cleaning Filter Installation Replacing dirty Air cleaning fi lters Replace fi lters with the following components (purchased separately). 1. Open the Intake Grille and remove the Air ● APPLE-CATECHIN FILTER : UTR-FA13-1 fi lters. ● ION DEODORIZATION FILTER: UTR-FA13-2 1.
  • Page 15: Troubleshooting

    TROUBLESHOOTING In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical WARNING breaker or disconnect the power supply plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to ensure that power is completely off.
  • Page 16 TROUBLESHOOTING Symptom Items to check See Page CHECK ONCE Doesn’t operate at all: ● Is the Power Supply Plug disconnected its outlet? MORE ● Has there been a power failure? — ● Has a fuse blown out, or a circuit breaker been tripped? ●...
  • Page 17: Operating Tips

    OPERATING TIPS AUTO Restart In Event of Power Interruption ● The air conditioner power has been interrupted by a power ● If a power failure occurs during TIMER operation, the timer will failure. The air conditioner will then restart automatically in be reset and the unit will begin (or stop) operation at the new its previous mode when the power is restored.