7. Various control

7-1. Auto restart

When the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents
memorized when the power is
interrupted
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time
(set by wireless remote
controller)
Airflow direction setting
Swing
ECONOMY operation
10 °C HEAT operation
Outdoor low noise operation
Remote control setting
WLAN indicator lamp setting

7-2. MANUAL AUTO operation

When the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
When MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode
Fan mode
Timer mode
Setting temperature
Horizontal louver setting
Vertical louver setting
SWING
ECONOMY
Human sensor
7-1. Auto restart
Wall mounted (For other than
KGTB, 07–14KMTB, and KMCC),
Floor
Wall mounted, Floor
Continuous (no timer setting available)
Standard
According to memory position
- (04-68) -
Compact cassette,
Mini duct, Slim duct,
Wall mounted (For KGTB, 07–
14KMTB, and KMCC),
Ceiling
Compact cassette, Mini duct,
Slim duct, Ceiling
Auto changeover
AUTO
24°C
According to memory position
Off
Off
Off
7. Various control