TROUBLESHOOTING
NORMAL
Airfl ow is weak or stops:
FUNCTION
Water is produced from
the outdoor unit:
CHECK ONCE
Doesn't operate at all:
MORE
Poor Cooling performance:
The unit operates
differently from the Remote
Controller's setting:
If the problem persists after performing these checks, or if you notice burning smells, or both the ORERATION Indicator Lamp (Fig. 3
5) and the TIMER Indicator Lamp (Fig. 3 6) fl ashes, or only the TIMER Indicator Lamp (Fig. 3 6) fl ashes, immediately stop operation,
disconnect the Power Supply, and consult authorized service personnel.

OPERATING TIPS

Operation and Performance

Heating Performance
● This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi cient
heating performance is being produced, we recommend you
use this air conditioner in conjunction with another kind of
heating appliance.
● Heat-pump air conditioners heat your entire room by recircu-
lating air throughout the room, with the result that some time
may be required after fi rst starting the air conditioner until the
room is heated.
En-15
Symptom
● When Heating operation is started, fan speed is temporarily very low,
to allow internal parts to warm up.
● During Heating operation, if the room temperature rises above the
thermostat setting, the outdoor unit will stop, and the indoor unit will
operate at very low fan speed. If you wish to warm the room further,
set the thermostat for a higher setting.
● During Heating operation, the unit will temporarily stop operation (be-
tween 7 and 15 minutes) as the Automatic Defrosting mode operates.
During Automatic Defrosting operation, the OPERATION Indicator
Lamp will fl ash.
● The fan may operate at very low speed during Dry operation or when
the unit is monitoring the room's temperature.
● During SUPER QUIET operation, the fan will operate at very low speed.
● In the monitor AUTO operation, the fan will operate at very low speed.
● During Heating operation, water may be produced from the outdoor
unit due to Automatic Defrosting operation.
Symptom
● Is the Power Supply Plug disconnected its outlet?
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the timer operating?
● Is the Air Filter dirty?
● Air the air conditioner's intake grille or outlet port blocked?
● Did you adjust the room temperature settings (thermostat) correctly?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight
to enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
● Is the unit set for SUPER QUIET operation?
● Are the Remote Controller's batteries dead?
● Are the Remote Controller's batteries loaded properly?
Problem
Items to check
Microcomputer-controlled Automatic Defrosting
● When using the Heating mode under conditions of low outdoor
temperature and high humidity, frost may form on the outdoor
unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this unit is
equipped with a Microcomputer-controlled Automatic Defrost-
ing function. If frost forms, the air conditioner will temporarily
stop, and the defrosting circuit will operate briefl y (for about
7-15 minutes).
During Automatic Defrosting operation, the OPERATION
Indicator Lamp (red) will fl ash.
See Page
15
6
6
6
15
See Page
8 - 9
6
5