Fujitsu ASBA24LFC Operating Manual

Fujitsu ASBA24LFC Operating Manual

Room air conditioner wall mounted type heat & cool model (reverse cycle) indoor & outdoor unit

Advertisement

OPERATING MANUAL
MANUAL DE FUNCIONAMIENTO
MANUAL DE INSTRUÇÕES
ROOM AIR CONDITIONER

WALL MOUNTED TYPE

HEAT & COOL MODEL
(REVERSE CYCLE)
Indoor Unit
ASBA24LFC
ASBA30LFC
Outdoor Unit
AOBR24LFL
AOBR30LFT
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
GUARDE ESTE MANUAL DE USO PARA
FUTURAS CONSULTAS
GUARDE ESTE MANUAL DE FUNCIONANENTO
PARA REFERÊNCIA FUTURA
FUJITSU GENERAL LIMITED
P/N9315345318-03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASBA24LFC and is the answer not in the manual?

Questions and answers

Summary of Contents for Fujitsu ASBA24LFC

  • Page 1: Wall Mounted Type

    HEAT & COOL MODEL (REVERSE CYCLE) Indoor Unit ASBA24LFC ASBA30LFC Outdoor Unit AOBR24LFL AOBR30LFT KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA FUJITSU GENERAL LIMITED P/N9315345318-03...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........En-1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS ......En-2 AIR CIRCULATION ..........En-10 NAME OF PARTS ..........En-3 SWING OPERATION .......... En-11 PREPARATION .............En-5 COIL DRY OPERATION ........En-11 OPERATION ............En-6 CLEANING AND CARE ........En-12 TIMER OPERATION ..........En-8 TROUBLESHOOTING ........En-14 SLEEP TIMER OPERATION .........En-9 OPERATING TIPS ..........En-15 MANUAL AUTO OPERATION .......En-9...
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS INVERTER OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION) At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit Three-dimensional control over air direction swing is possible automatically switches to a low power setting for economic and through dual use of both an UP/DOWN air direction swing and comfortable operation.
  • Page 4: Name Of Parts

    NAME OF PARTS Fig. 1 ‹ - • § Ž © “ ® MANUAL AUTO Fig. 2 OPERATION TIMER COIL DRY Fig. 3 Fig. 5 Fig. 4 Fig. 6 Fig. 7 To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current operation.
  • Page 5: Name Of Parts

    NAME OF PARTS Fig. 1 Indoor Unit Fig. 6 Remote Controller 1 Operating Control Panel (Fig. 2) J SLEEP button 2 MANUAL AUTO button K MASTER CONTROL button ● L SET TEMP. button ( When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced M COIL DRY button cooling operation will start.
  • Page 6: Preparation

    PREPARATION CAUTION! Load Batteries (Size AAA R03/LR03 × 2) * ● Take care to prevent infants from acciden- tally swallowing batteries. Press and slide the battery compartment lid on the ● When not using the Remote Controller for an extended period, remove the batteries to reverse side to open it.
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button (Fig.6 R ). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5 ) will light. The air conditioner will start operating. Press the MASTER CONTROL button (Fig.6 K ) to select the desired mode.
  • Page 8 OPERATION To Stop Operation Press the START/STOP button (Fig. 6 R ). The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation AUTO: ● When AUTO CHANGEOVER operation fi rst selected, the fan will operate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Controller is set to the correct current time (☞ P. 5). To Use the ON timer or OFF timer Press the START/STOP button (Fig. 6 R) To Cancel the Timer (if the unit is already operating, proceed to step 2).
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP Timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER MODE button to select “CAN- SLEEP button (Fig.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION ● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Controller. ● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airfl ow-direction louvers have stopped mov- ing.
  • Page 12: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button (Fig. 6 U). The SWING Display (Fig. 7 d) will light. Each time the SWING button is pressed, the swing operation will change in the following order.
  • Page 13: Cleaning And Care

    CLEANING AND CARE ● Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord. CAUTION! ● Be sure the Intake Grille (Fig. 1 8) is installed securely. ● When removing and replacing the air fi lters, be sure not to touch the heat exchanger, as personal injury may result.
  • Page 14 CLEANING AND CARE 3. Replace the Air Filter and close the Intake 3 Engage the four fi xing locations at the top and bottom of the air cleaning fi lter frame with the hooks of the air fi lter. Grille. 1 Align the sides of the air fi...
  • Page 15: Troubleshooting

    CLEANING AND CARE In regard to the Air Cleaning Filters Please buy delicated deodorizing fi lter (UTR-FA13-2) (Sold separately) when exchanging the fi lters. POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet) ● The Air Cleaning Filters are disposable fi lters. (They can not Maintenance of Deodorizing Filters be washed and reused.) ●...
  • Page 16: Operating Tips

    TROUBLESHOOTING Symptom Problem See Page NORMAL Airfl ow is weak or stops: ● When Heating operation is started, fan speed is temporarily very low, FUNCTION to allow internal parts to warm up. ● During Heating operation, if the room temperature rises above the —...
  • Page 17: Auto Restart

    ● If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the outdoor unit may stop operation for certain period of time. SPECIFICATIONS MODEL INDOOR UNIT ASBA24LFC ASBA30LFC OUTDOOR UNIT AOBR24LFL AOBR30LFT TYPE HEAT &...