Clearances To Combustibles - Quadra-Fire Santa Fe Pellet Stove Owner's Manual Installation And Operatio

Santa fe pellet stove
Table of Contents

Advertisement

R
B. Clearances to Combustibles (UL and ULC)
A
B
Straight Back Against
Wall
A
Back Wall to Appliance
B
Side Wall to Appliance
Corner Installation
C
Walls to Appliance
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter
D
F
E
Vertical Installation
D
Back Wall to Flue Pipe
E
Side Wall to Cast Top
F
Back Wall to Appliance
Corner Installation
G
Walls to Appliance
H
Side Wall to Flue Pipe
Page 10
C
C
Inches
Millimeters
2
51
6
152
Inches
Millimeters
2
51
H
G
G
Inches
Millimeters
3
76
6
152
7
178
Inches
Millimeters
2
51
3
76
7050-128G
Santa Fe Pellet Stove
Alcove Installation
Minimum Alcove Height
Minimum Alcove Side Wall
Minimum Alcove Width
Maximum Alcove Depth
Dimension to Corner
I
Flue Center Line
J
Back of Top Vent Adapter
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
NOTE:
Illustrations refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Inches
Millimeters
43
1092
6
152
38
965
36
914
I
J
C L
Inches
Millimeters
8-1/2
217
9-1/8
232
May 12, 2014