Note: In the following step, the upper and lower
fan guides in the fan plenum will expand when the
condenser fan is pulled out.
Upper Fan Guide
Lower Fan Guide
6. Grasp and pull the condenser fan straight out
from guides in the fan plenum.
Fan Removed

3-Way Valve Coil

The 3-way valve coil is attached to the top of the
3-way valve.
To remove the 3-way valve coil:
1. Remove the machine compartment cover. (See
Machine Compartment Cover
2. Remove the 1/4-in. hex-head screw that
attaches the 3-way valve bracket and spacer to
the refrigerator.
Fan Plenum
3. Carefully reposition 3-way valve and drier to
gain better access to the condenser fan and
valve wire harnesses.
4. Disconnect the wire harness attached to the
back of the 3-way valve coil.
5. Disconnect the fan and valve wire harness from
the cabinet.
6. Using a fl at blade screwdriver, simultaneously
pry out the tab and lift the 3-way coil from the
valve assembly.
– 60 –
.)
Spacer (behind bracket)
Disconnect
Disconnect