Download Print this page

Graco ST Max 395 Quick Operator's Manual page 2

Hide thumbs Also See for ST Max 395:

Advertisement

SPRAYING
Turn safety lever
of gun to OFF.
SHUTDOWN AND CLEANUP
Trigger gun
Set power
until pressure
switch to OFF.
is relieved.
Unscrew tip & guard from
gun. Clean gun filter, inlet
Place drain tube
screen, tip, guard and
manifold filter with water
and siphon tube
in pail of water.
and brush.
WASTE
Place drain tube in waste
Set power switch to ON,
pail and siphon tube in
and increase pressure
container of Pump Armor
until sprayer starts.
GRACO N.V. Industrieterrein Oude Bunders
Slakweidestraat 31 • B-3630 Maasmechelen
Tel: +32 (89) 770 700 • Fax: +32 (89) 770 777
E-mail: info@graco.be • http://www.graco.be
Point gun at area to be sprayed about 30 cm from surface, and begin moving gun before triggering. A good spray pattern is evenly
distributed as it hits surface. Set pressure just high enough to spray without heavy edges. Use smaller tip size for thinner material
and a larger tip size for thicker material if pressure adjustment cannot achieve even spray pattern.
Turn prime valve
Remove gun
to Prime position (down).
filter assembly.
Turn pressure control knob to
lowest setting, set power switch
to ON, and increase pressure until
sprayer starts. Let sprayer run and
flush itself for 2 minutes.
t
As soon as Pump Armor
comes out of drain tube,
set power switch to OFF.
Remove manifold
filter and spacer.
Keeping gun triggered
Keep gun triggered
into water pail, turn prime
into pail for 1 minute,
valve to Spray position
until water coming out
(horizontal).
of gun is clean.
Screw inlet screen onto
siphon tube, replace
Wipe outside of sprayer,
manifold filter and spacer,
hose and gun with rag
soaked in water or
and assemble gun with
mineral spirits.
filter, tip and guard.
© 2002, 2006 Graco N.V. · Form No. 328007 E (rev.C) · 01/08 · Printed in Europe.
All information, illustrations, and specifications in this document are based on the latest product information
available at the time of publication. The right is reserved to make changes at any time without notice.
Assemble gun
Unscrew inlet screen
without filter.
from siphon tube.
Set power switch to OFF, turn
pressure control knob to lowest
setting, and turn prime valve to
Prime position (down).
Fill throat packing
nut with TSL.
Graco is certified ISO 9001.

Advertisement

loading

This manual is also suitable for:

St max ii 495St max ii 595