Force (in pounds) = 0.0042 . A . v
Where A is the surface area in square feet and v is the wind speed in miles per hour.
The lateral force produced by a single PTP 500 Series bridge (integrated or connectorized
model) at different wind speeds is shown in Table 5 and Table 6.
PTP 500 Series
Bridge - Integrated
PTP 500 Series
Connectorized
PTP 500 Series
Bridge - Integrated
PTP 500 Series-
Connectorized
NOTE
When the connectorized version of PTP 500 Series bridge is used with external
antennas, the figures from the antenna manufacturer for lateral force should be
included to calculate to total loading on the mounting structure.
4.7.2 Capabilities of the PTP 500 Series Bridges
The structure and mounting brackets of the PTP Series systems are capable of withstanding
wind speeds up to 151mph (242 kph). The installer should ensure that the structure to which
the PTP 500 Series Bridge is fixed to is also capable of withstanding the prevalent wind
speeds and loads.
2
Table 5 - Lateral Force – Imperial
Largest Surface
Lateral Force (Pound) at wind speed (mph)
Area (sq ft)
80
1.36
36.6
1.00
26.9
Table 6 - Lateral Force – Metric
Largest Surface
Lateral Force (kg) at wind speed (m/s)
Area (sq m)
30
0.130
12
0.093
9
35
4 Planning Considerations
100
120
140
57.1
82.3
146.2
42
60.5
107.5
40
50
60
22
34
49
16
24
35
150
228.5
168.0
70
66
48