A.O. Smith 710 ASME Service Manual page 41

On-demand water heater
Table of Contents

Advertisement

Error Code
Disconnected AFR rod
391
1 AFR rod fault
V isual inspection: connection / breakage of wires, soot on it.
Error Code
Flow sensor failure
(Only Easy-link and Multi-unit system)
441
1 Flow sensor failure
V isual inspection: connection/ breakage of wires andor debris on impeller.
Check voltage / resistance between (red & black) or (white & black)
Error Code
Fault of driving circuit for main gas solenoid
valve (MV)
510
(The computer checks the condition of the main
gas valve immediately after every operation)
1 PCB and /or main gas valve fault
V isual inspection of gas valves: connection / breakage of wires.
Normal: 78 to 100 VDC between COM (blue) & #3 (light blue)
(during operation)
V isual inspection of PCB: connection / breakage of wires and/or burn marks
on the computer board.
2 Main gas valve fault
Malfunction description
Malfunction description
Malfunction description
710 / 710 ASME Service Manual
Turn off the power or water supply
Diagnosis
(Refer to section 10-6)
Turn off the power or water supply
Diagnosis
(Refer to section 10-8)
Turn off the power supply
Diagnosis
(Refer to section 10-4 & 10-14)
41