Overheat Cutoff Fuse - A.O. Smith 710 ASME Service Manual

On-demand water heater
Table of Contents

Advertisement

10-12. Overheat cutoff fuse

Unit Part #
Function
Failure event
Effects on the water
heater if the overheat
cutoff fuse fails
Error
codes
when
overheat
cutoff
fuse
fails
Diagnostic
Color / Number of wires
Solder will melt at temperature exceeding 430
#403
AOS Part #
The overheat cutoff fuse contains solder with a melting point of 430˚F
(221˚C).
Detects excessive temperatures within the water heater, especially around
the heat exchanger and combustion chamber. Upon detection,
communication between the computer board and gas valves will sever,
shutting down the water heater instantly. The "111" or "121" error code
will display.
1. Unable to detect the excessively high temperatures within the water
heater.
1. Flames from burner may penetrate a ruptured/damaged heat exchanger.
2. Gas valves will not operate.
111
1. Visual inspection: connection / breakage of wires.
2. Check voltages and resistance: proper range of values shown below.
Blue-Blue
Less than 1.0 Ω
710 / 710 ASME Service Manual
319143-286
˚F (±9˚F) / 221˚C (±5˚C)
3 1- 1 /2 " ( 80 0 mm )
27
CONFIDENTIAL
Ver. 1.00
Checkpoint
C2
121

Advertisement

Table of Contents
loading

This manual is also suitable for:

710

Table of Contents