A.O. Smith 710 ASME Service Manual page 38

On-demand water heater
Table of Contents

Advertisement

Error Code
8 Check if there is dust and lint in burner and heat exchanger, when the water
heater has been installed in laundry room.
101
9 Check if there is grease and dirt in burner and fan motor, when the water
heater has been installed in restaurant.
10 Check the manifold pressure in the water heater.
Error Code
Ignition failure
111
1 Check gas supply and inlet gas pressure (Refer to section 1)
2 Check the igniter (Refer to section 10-17)
V isual inspection: connection / breakage of wires and/or observed weak
Error code is
spark.
[1] Cracks / soot on igniter rod
shown after
[2] Improper gap between burner & igniter rod
three failed
Normal gap: 0.16" (4mm)
attempts at
[3] PCB fault
iginition
Normal: 90 to 110 VAC at #7 (purple-purple) (during ignition)
3 PCB fault
[1] No voltage to main gas solenoid valve (MV)
Normal: 78 to 100 VDC between COM (blue) & #3 (light blue)
(during operation)
[2] No voltage to gas solenoid valve (SV
Normal: 78~100 VDC between COM (blue) & #53 (orange)
(during operation)
[3] No voltage to gas proportional valve (VG
Normal: 1~15 VDC between white & red (during operation)
4 Gas solenoid valve fault
[1] Main gas solenoid valve (MV) fault
Normal: 0.9 to 1.3 kΩ between COM (blue) & #3 (light blue)
[2] Gas solenoid valve (SV
Normal: 1.3 to 1.9 kΩ between COM (blue) & #53 (orange)
[3] Gas proportional valve (VG
Normal: 1 to 15 VDC between white & red (during operation)
5 Disconnected / damaged O.H.C.F. (Refer to section 10-12)
V isual inspection: connection / breakage of wires.
Normal: 1 Ω or less between blue & blue
Malfunction description
) fault
2
) fault
0
710 / 710 ASME Service Manual
Diagnosis
Turn off the power or water supply
Diagnosis
)
2
)
0
38
CONFIDENTIAL
Ver. 1.00
Checkpoint
Cancellation method
Checkpoint
B
C
H1
C
H1
C2