Wiring Diagram Checkpoints For Diagnosis - A.O. Smith 710 ASME Service Manual

On-demand water heater
Table of Contents

Advertisement

7. Wiring diagram check points for diagnosis
Check-
Parts and Description
point
A, A1
100 V Power supply
A2,A3
120 V Power supply
B
Igniter
C
Gas valves
C1
Hi-Limit switch
C2
Overheat cutoff fuse
D1
Easy-link connectors
Multi-unit link
D2
connectors
E1
Mixing thermistor
E2
Output thermistor
E3
Inlet thermistor
F
Remote controller
G
Fan motor
H1
Gas proportional valve
Color of wires
White – Black (A)
Brown – Brown (A1)
Black - White
Purple – Purple
Light blue - blue at COM (MV)
Green - blue at COM (SV1)
Orange - blue at COM (SV2)
Red - blue at COM (SV3)
Blue - Blue
Blue - Blue
White - White
Red – Red
Blue – Blue
Purple- Purple
Orange -Orange
Black - Black
Black - Black
Black - Black
Black - White
Red - Blue
Yellow - Blue
Orange - Blue
White - red
10
CONFIDENTIAL
710 / 710 ASME Service Manual
Normal Range
90 to 110 VAC
108 to 132 VAC
90 to 110 VAC
78 to 100 VDC (during operation)
/ 0.9 to 1.3kΩ
78 to 100 VDC (during operation)
/ 1.3 to 1.9kΩ
78 to 100 VDC (during operation)
/ 1.3 to 1.9kΩ
78 to 100 VDC (during operation)
/ 0.9 to 1.7kΩ
Less than 1 VDC and less than 1 Ω
Less than 1 VDC and less than 1 Ω
15 VDC
15 VDC
(during Easy-link operation)
15 VDC
(during Multi-unit operation)
See table on p.12
11 to 25 VDC
110 to 160 VDC
13 to 17 VDC
2 to 6.5 VDC
1 to 15 VDC (during operation)
and
20 to 40 Ω
Ver. 1.00

Advertisement

Table of Contents
loading

This manual is also suitable for:

710

Table of Contents