In this way every time that you load a plu with reference of tare, the weight of the programming tare will be substracted
to the total weight on the plate, example:
You have a program tare of 0.04 lb. in the PLU "sugar".
1.
Assure it the indicator of weight is in zero weight.
2.
Load the "sugar" PLU .
3.
Place the container with the sugar that weigh 2.24 lb, when you place the container you will see in the
indicator of weight 2.20 lb, due to the programming tare was already substracted from the gross weight on the
plate.
When you remove the container, the scale will return to zero weight and will erase the PLU, as well as the
corresponding tare, remaining the scale ready for the next operation.
Note: When you use the programming tares you won´t operate the function tare manually.

REFERENCING TO ZERO WEIGHT

This function has two applications
a)
Permanent tare, when you wish to weigh some products in the same container, in several occasions, you will
use this function, to cancel this function just remove the weight from the plate, and press the
Also, as the tare, this function is subtractive. is substracted of the maximum capacity for example: for a scale of
40lb, if you tare a weight of 5lb, the scale only can weigh to 35 lb.
b)
Due to voltage variations or some other factors, It is possible that without having any product on the plate
appear in display any quantity or the ZERO indicator not appear in display, then press the
scale will reference to zero, and the ZERO indicator appear automatically.
INTRODUCING NON-PLU PRODUCTS
To enter prices of products that are not programmed in memory, just type the price using the operation keypad.
When you wish to introduce an unweighed non-plu first press the
result of the price per one piece, this key is just for one piece. (you can multiply several pieces using the function
(see pag.16).
It is important to mention that every time that you add or print a label without load a PLU, will print "several
products" in the corresponding space of the product name and this sale will appear in your reports as several products
or pieces.
Note: To enter non-plu products, you must be sure to enable this function into the configuration option (see
page 20 from the programming manual).
ERASING PRICES OR PLU'S
You can clear it in two ways: Manual and Automatically
a)
Manual.- If you press by error a wrong price or load a PLU not desired, just press the
price or PLU.
b)
Automatically.- After remove the weight from the plate, automatically the price or PLU will be cleared, except if
the FIXED PRICE function is enabled.
key in this way the total showed is the
11
key again.
key and your
key and type the new