7.
Installation - Location - Start up
Crema Compact and Digital

7.6 Failure message

Finite brewtime for each group are 240 seconds.
If you reach this time indicator lamp start blinking and the group will be blocked.
If the flowmeter operate incorrect, the indic. lamp above the button you pressed will start blinking.
If this should happen you can´t get any doses when machine is brewing.
Still you can do a manuel brewing, by using button 1.
On Model Digital, by using the manuel brew switch (pos. 5 page 3).
To avoid flooding or overflow: The autom water system is equipped with a safety device.
If the water level control solenoid valve remains open for more than 120 seconds; it is automatically
switched off and the fault is signalled by indic. lamps are blinking on all the push-button pads.
To restart, the machine power must be removed for at least 5 seconds, and then start
the machine again.
If failure message repeats, please contact authorized personnel or your retail dealer.