Menu level 1
Menu level 2
TEST ALL
TEST*
TEST PAN/TILT
TEST EFFECTS
RESET
LAMP ON/OFF
STROBE
DIMMER
DIMMER FINE
CYAN
MAGENTA
YELLOW
CTC
COLOR WHEEL
IRIS
MANUAL
BARNDOOR 1
CONTROL*
BARNDOOR 2
BARNDOOR ROT
ZOOM
ZOOM FINE
FOCUS
FOCUS FINE
PAN
PAN FINE
TILT
TILT FINE
CONTROL
ERROR LIST
PT FEEDBACK
FAN CLEAN
CALIBRATION
SERVICE
USB
* Menu available only when the fixture is connected to mains power. All other menus are available in mains- and battery-powered
operation.
Menu level 3
Menu level 4
RESET
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Empty or up to 20 errors
ON
OFF
ON/OFF
PT AT END STOP ... TILT
LOAD DEFAULTS
SAVE DEFAULTS
NO DEVICE
UPDATING FILES
AVAILABLE
VER. 1.0.0 ...
FIRMWARE
VER. X.X.X
Table 2: Control menus
Control panel menus
Notes (Default settings in bold print)
Run test sequence of all functions. Press
Escape button to stop test
Run test sequence of pan and tilt
functions. Press Escape button to stop test
Run test sequence of all effects. Press
Escape button to stop test
Click jog wheel to reset fixture
Manually strike/douse lamp
Set shutter/strobe effect (default = 30)
Set dimmer opening
Set dimmer opening, fine (LSB)
Add cyan
Add magenta
Add yellow
Adjust color temperature control (add
warmth)
Select color filter
Set iris aperture
Set internal barndoor 1 position
Set internal barndoor 2position
Set barndoor rotation
Set zoom (default = 128)
Set zoom, fine (LSB, default = 128)
Set focus
Set focus, fine (LSB, default = 128)
Set pan angle (default = 128)
Set pan angle, fine (LSB, default = 128)
Set tilt angle (default = 128)
Set tilt angle, fine (LSB, default = 128)
Send value on DMX control channel
(default = 0)
Display any errors in memory
Enable pan/tilt position feedback systems
Disable pan/tilt position feedback
Activate fan cleaning
Set individual effects to calibration
positions (approx. +/- 5% offset available)
Load factory default calibration settings
Replace factory default calibration settings
with current calibration settings
No USB device present or no firmware on
USB device
Fixture updating internal memory from
USB device
Select firmware from versions stored in
internal memory: select version, then click
on jog wheel and confirm your choice to
update
25