6. Insert the upgrade card into the connector opening with the arrow facing towards the pins, then
push it in firmly until the contact pins are completely inside the flash card and securely
attached to the connector (FIG. 21).
Under-side groove
located below
Insert with arrow
facing towards
the connector pins
FIG. 21 Removing the Compact Flash card
7. To complete the upgrade process, close and re-secure the Integrated Controller enclosure using
the procedures outlined in the following section.
Any new internal card upgrade is detected by the Controller only after power is
cycled.

Closing and Securing the Integrated Controller

Once the card has been replaced, close and re-secure the outer housing:
1. Align the cover over the unit and gently slide-down the cover until the chassis housing
openings are aligned over their respective openings along both the sides and top of the unit.
2. Begin pushing-down the housing until the cover is securely positioned over circuit board.
3. Insert the chassis housing screws into their respective locations, as shown in FIG. 20.
4. Securely tighten these screws by using a grounded screwdriver turning in a clockwise
direction.
5. Re-install all connectors and apply power.