AMX NetLinx Integrated Controller NI-4000 Instruction Manual page 14

Amx corporation netlinx integrated controllers (ni-2000, ni-3000, and ni-4000) instruction manual
Hide thumbs Also See for NetLinx Integrated Controller NI-4000:
Table of Contents

Advertisement

Introduction
NI-3000 Specifications (Cont.)
Rear Panel Components:
RS-232/422/485 (Ports 1 -7)
ICSNet
ICSHub Out
Relay (Port 8)
Digital I/O (Port 17)
IR/Serial (Ports 9-16)
8
• Seven RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.
• Channel range = 1-255
• Channels 1-254 provide feedback
• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
• Output data format for each port is selected via software
• Seven DB9 connectors provide RS-232/422/485 termination
• Two RJ-45 connectors for ICSNet interface
• Single RJ-45 connector provides data to another Hub connected to the
Controller
• Eight-channel single-pole single-throw relay ports
• Each relay is independently controlled.
• Supports up to 8 independent external relay devices
• Channel range = 1-8
• Each relay can switch up to 24 VDC or 28 VAC @ 1 A
• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay
termination
• Eight-channel binary I/O port for contact closure
• Each input is capable of voltage sensing. Input format is software
selectable.
• Interactive power sensing for IR ports
• Channel range = 1-8
• All inputs are assigned to respective IR/Serial ports for "automatic" power
control through the use of software commands. Power control is provided
via commands such as: 'PON', 'POF', 'POD', 'DELAY', I/O Link etc.).
• Contact closure between GND and an I/O port is detected as a PUSH
• When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as
a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE
• When used as an output - each I/O port acts as a switch to GND and is
rated at 200 mA @ 12 VDC
• One 10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port
termination
• Eight IR/Serial control ports support high-frequency carriers up to
1.142 MHz
• Each output is capable of two electrical formats: IR or Serial
• Eight IR/Serial data signals can be generated simultaneously.
• Channel range = 1-32,767
• Channels 1-128 (output): IR commands
• Channels 129-253: used as reference channels
• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
• Channel 255 (feedback): Power status (when IO Link is set)
• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port
termination
NetLinx Integrated Controllers

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netlinx ni-2000Netlinx ni-3000

Table of Contents