min. temp. cooling flow
Set the minimum temperature on the supply temperature to the climate system
during cooling operation. This means that F1245 never calculates a temper-
ature lower than that set here.
cooling flow temp. at +20 °C
Set the desired temperature on the flow temperature to the climate system
during cooling operation when the outdoor temperature is +20 °C. F1245
then attempts to get as close to the set temperature as possible.
coolant flow line at +40°C
Set the desired temperature on the flow temperature to the climate system
during cooling operation when the outdoor temperature is +40 °C. F1245
then attempts to get as close to the set temperature as possible.
time betw. switch heat/cool
Here you can set how long F1245 is to wait before it returns to heating mode
when the cooling demand has ceased or vice versa.
heat at room under temp.
Caution
This setting option only appears if a room temperature sensor is connected
to F1245 and has been activated.
Here you can set how far the room temperature can drop below the desired
temperature before F1245 switches to heating operation.
cool at room over temp.
Caution
This setting option only appears if a room temperature sensor is connected
to F1245 and has been activated.
Here you can set how high the room temperature can increase above the
desired temperature before F1245 switches to cooling operation.
Chapter 3 |
F1245 – at your service
NIBE™ F1245
41