Nibe F1245 User Manual page 37

Uk 1x230v ground source heat pump
Hide thumbs Also See for F1245:
Table of Contents

Advertisement

°C
70
60
Maximivärde
50
40
30
10
0
Caution
Underfloor heating systems are normally
between 35 and 45 °C.
Check the max temperature for your floor with your installer/floor supplier.
The figure at the end of the curve indicates the curve slope. The figure beside
the thermometer gives the curve offset. Use the control knob to set a new
value. Confirm the new setting by pressing the OK button.
Curve 0 is an own heating curve created in menu 1.9.7.
To select another heat curve (slope):
NOTE
If you only have one heating system, the number of the curve is already
marked when the menu window opens.
1.
Select the system (if more than one) for which the heat curve is to be
changed.
2.
When the system selection has been confirmed the heat curve number
is marked.
3.
Press the OK button to access the setting mode
4.
Select a new heating curve. The heat curves are numbered from 0 to 15,
the greater the number, the steeper the slope and the greater the supply
temperature. Heating curve 0 means that
used.
Chapter 3 |
F1245 – at your service
Minimivärde
- 10
- 20
- 30
- 40°C
UTETEMPERATUR
Flow line temperature– maxim-
um and minimum values
Because the flow line temperature
cannot be calculated higher than the
set maximum value or lower than the
set minimum value the heating curve
flattens out at these temperatures.
max flow line temperature
own curve
set
(menu 1.9.7) is
NIBE™ F1245
35

Advertisement

Table of Contents
loading

Table of Contents