CONTENTS INTRODUCTION OPERATION 7 Basic Function OVERVIEW 8 Removal of AC (Mains) Power 9 Battery care DEFINITIONS 10 System Integrity Check APPLICATION 11 Visual Indicators POSITIONING WHAT TO DO IF YOUR WI-SAFE SYSTEM ALARMS LIMITATIONS REPAIR HOW TO INSTALL YOUR WI-SAFE SYSTEM TROUBLESHOOTING 1 Preparation...
The FireAngel range of products is constantly What is Wi-Safe? being expanded. Please visit www.fireangel.co.uk Wi-Safe is a FireAngel term to describe the to find out about the latest additions to our wireless, radio frequency (RF) communication product range.
IMPORTANT: This user manual OVERVIEW OF THE contains important information FIREANGEL WI-SAFE regarding the operation of your Strobe and HOME SAFETY SYSTEM Vibrating Alert System. If you are installing this COMPONENTS product for use by others, you must leave this manual (or a copy of it) with the end user.
The AC mains adaptor is rated at 230V 50Hz consists of a Receiver Box with integrated Strobe 0.075A input. Light, an AC mains adaptor and Vibrating Pad to be used in conjunction with FireAngel Wi-Safe DEFINITIONS smoke or carbon monoxide (CO) alarms. Strobe...
The Strobe and Alert System is only designed to receive Vibrating Alert System will only warn signals from FireAngel Wi-Safe smoke or CO of smoke or carbon monoxide if it receives a alarms. It will not respond to other models signal from a recognised active alarm.
• Where you can see the LED indicators on the and Vibrating Alert System will not operate in front of the alarm isolation (on its own), with non Wi- Safe FireAngel smoke or CO alarms or any alarms made by other CAUTION: Do not put the Strobe and Vibrating manufacturers.
Page 9
FireAngel WFSVP-629 has been designed to may not respond in a reasonable time if it is not detect a signal from any FireAngel product with a installed in the best position or if obstacles, such as Wi-Safe transmitter as soon as it is activated. We...
Page 10
The Wi-Safe Home Safety System may not WARNING: Use only the battery alarm before a dangerous CO level causes illness, included in this pack as it has been poisoning or death, as the CO may not reach the chosen specifically for this application. Use of CO alarm in time.
Page 11
Vibrating Pad. Make sure the Strobe section of the (See “Testing” on page 15). Receiver Box is not obstructed and the Vibrating NOTE: The Strobe and Vibrating Alert System, Pad is placed securely under the pillow/cushion so that it cannot slip underneath the bed or chair smoke and CO alarms should not be considered meaning it may not alert the person relying on it.
DANGER: Under no circumstances HOW TO INSTALL YOUR should this product be immersed in STROBE AND VIBRATING water, or used in an area where water may ALERT SYSTEM come into contact with the system. Preparation WARNING: The Strobe and Vibrating Alert System is intended for operation IMPORTANT: Make sure you have read and only on 230V AC, 50 Hz circuits.
Remove the battery cover from the back of the Connect the Rechargeable Receiver Box. Battery Locate the battery clip and connect the battery by aligning the terminals correctly and clip into WARNING: Connect battery with place. Place the battery into the Receiver Box and mains power disconnected.
Strobe and Vibrating Pad in the event that mains and secure the screw leaving the heads protruding power has been disconnected or has failed. Only so that the face of the head is 5mm away from use the battery supplied. The battery should the wall.
Box briefly and release (see page 14). that have a Wi-Safe interconnect function. To get you started quickly your FireAngel WFSVP-629 On releasing the button the Yellow and Red LEDs has been designed to detect a signal from any...
sequence will continue for around 4 minutes or alarm. When an alarm is testing the Red LED until the learn button is pressed again, which will on the alarm will flash rapidly and the alarm will switch off learn mode. sound.
Once confirmed the next alarm can be connected Testing by one person going to the alarm and pressing the test button again while the other person monitors Now the Receiver Box has been connected to the LEDs on the Receiver Box. all the alarms in the system you should test the functionality of the whole Wi-Safe system.
Page 18
instructions for that particular model. the Receiver Box and Vibrating Pad that the LED on the Receiver Box indicated an alarm and that NOTE: For CO alarms only the horn and battery the Vibrating Pad vibrated while they were away test is required, you do not need to carry out the testing the alarm.
OPERATION A On Standby with AC power connected B In Alarm WCO-628 Smoke Detected CO Detected POWER POWER FAULT FAULT ALARM ALARM POWER POWER POWER POWER FAULT FAULT FAULT FAULT ALARM ALARM ALARM ALARM LED status on Receiver Box Flashing Strobe and Vibration warning from Red ALARM LED on Vibrating Pad...
Page 20
from a Wi-Safe smoke alarm the red LED will Strobe and Vibrating Alert illuminate permanently, and the Vibrating Pad System Basic Function will vibrate for 2 seconds then there will be a 2 second pause, this pattern will continue until A On Standby with AC power connected the smoke alarm stops sending a signal.
signal has been reset or has stopped if the internal backup rechargeable battery. To ensure danger is no longer present. Only reset an correct operation the AC (mains) power must be alarm if you are certain there is no imminent restored as soon as possible.
The battery provided is rechargeable and • Adding further Wi-Safe products to the system is continuously charged when plugged into • Changing the battery in the Receiver Box the mains. Installation of a non-rechargeable (only when instructed by FireAngel technical battery is dangerous and may cause harm or support) damage. Visual Indicators System Integrity Check...
Strobe Smoke Indicates alarm signal from a Wi-Safe smoke or Red ALARM LED. Continuously illuminated when a smoke alarm in the system is in “alarm” mode. carbon monoxide alarm. (See “Basic Function” section). Power Carbon Monoxide Green POWER LED. In normal conditions (AC Red ALARM LED.
If the Strobe and Vibrating Alert System has WHAT TO DO IF YOUR been triggered by a remote signal from a carbon STROBE AND VIBRATING monoxide (CO) alarm the red ALARM LED on ALERT SYSTEM ALARMS the receiver box will flash 4 times rapidly followed by a pause.
Page 25
their chances of escaping safely. Go over the leaving the house. Carry out a head count. following rules with your children each time you • Call the fire service on 999 as soon as possible have a fire drill. This will help everyone remember from outside your house. If possible use a them in case of a real emergency.
Page 26
Contact your local fire service. They will give you monoxide (CO) poisoning, and contact the more ideas about how to make your home safer proper authorities to resolve all CO problems. from fires and how to plan your family’s escape. NEVER IGNORE A LOW-LEVEL OR HIGH- LEVEL ALARM.
Page 27
Write your fuel supplier’s emergency number the appliance. These may include gas and here; wood-burning fireplaces, all gas appliances, and barbecues. • Note the reading on the display. • Silence the alarm and turn off the low-level • Do not re-enter the property until the alarm icon by pressing the Test/Reset button. has stopped. • Do not use the appliance again until it has • Get medical help immediately for anyone been checked by an expert. In the case of gas suffering the effects of carbon monoxide appliances this must be a CORGI registered poisoning, (headache, nausea), and advise that...
27 & 28. If you cannot solve the problem, conditions. If during normal operation the yellow please call the FireAngel Technical Support Line LED flashes twice every 5 seconds while the for advice on 024 7623 6663 or visit the ‘Support’...
TROUBLESHOOTING Problem Solution Upon connection of the This is normal if the battery capacity has become very low in transit. Switch the AC (mains) power on to charge the rechargeable rechargeable battery the yellow LED flashes twice battery. The yellow LED may continue to flash twice every 5 every 5 seconds seconds for up to 72 hours (until the battery is sufficiently charged).
Page 30
When testing the system, the This is normal and can vary even when carrying out multiple tests length of time that the Strobe with the same alarm. flashes and the Vibrating Pad vibrates varies The Strobe and Vibrating Alert Ensure that the smoke/CO alarm is working and does not have a System does not respond to low battery.
FireAngel Limited warrants to the original purchaser that its enclosed Wi-Safe Strobe and Vibrating Alert System WFSVP-629 be free from Please recycle where facilities exist. Check with defects in materials and workmanship under your local authority, retailer or manufacturer for...
Page 32
Except for death or personal purchaser from the date of original retail purchase injury, FireAngel Limited shall not be liable for any and is not transferable. Proof of purchase is loss of use, damage, cost or expense relating to required.
RETURNS System under warranty send it suitably packed and with the battery disconnected with postage We recommend that you contact the FireAngel prepaid; a note indicating the returns authority Technical Support Line in the first instance on 024 number and describing the nature of the difficulty,...
Need help?
Do you have a question about the WFSVP-629 and is the answer not in the manual?