Wi-safe vibrating alert system

Advertisement

WVP-626 User Manual
Wi-Safe
Vibrating Alert
System
Part of the Wi-Safe Home Safety
System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wi-Safe WVP-626 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FireAngel Wi-Safe WVP-626

  • Page 1 WVP-626 User Manual Wi-Safe Vibrating Alert System Part of the Wi-Safe Home Safety System...
  • Page 2: Table Of Contents

    CONTENTS 7 Basic Function INTRODUCTION 8 Removal of AC Mains Power OVERVIEW 9 Battery care 10 Battery Replacement DEFINITIONS 11 System Integrity Check APPLICATION 12 Visual Indicators POSITIONING WHAT TO DO IF YOUR WI-SAFE VIBRATING ALERT SYSTEM ALARMS LIMITATIONS REPAIR HOW TO INSTALL YOUR WI-SAFE VIBRATING ALERT SYSTEM TROUBLESHOOTING...
  • Page 3: Introduction

    Congratulations! You’ve made a wise investment • Wi-Safe Ionisation Smoke Alarm WSI-601 in an innovative product and your personal safety. • Wi-Safe 10 Year Optical Smoke Alarm WSO- The Wi-Safe WVP-626 Vibrating Alert System is one of a new generation of domestic life safety • Wi-Safe 10 Year Ionisation Smoke Alarm WSI- products from FireAngel, which combines the latest technology and innovative design to provide • Wi-Safe Carbon Monoxide (CO) Alarm...
  • Page 4: Overview

    IMPORTANT: This user manual OVERVIEW OF THE contains important information FIREANGEL WI-SAFE regarding the operation of your Vibrating Alert HOME SAFETY SYSTEM System. If you are installing this product for use COMPONENTS by others, you must leave this manual (or a copy of it) with the end user.
  • Page 5: Definitions

    The FireAngel Wi-Safe Home Safety System 0.075A input. consists of a Receiver Box with integral Vibrating Pad to be used in conjunction with FireAngel DEFINITIONS Wi-Safe smoke or carbon monoxide (CO) alarms. Radio frequency, method of communication The smoke or CO alarms should be positioned in recommended locations specified in the user manuals accompanying those products.
  • Page 6: Application

    The Vibrating Alert System is only designed to receive System will only warn of smoke or signals from FireAngel Wi-Safe smoke or CO carbon monoxide if it receives a signal from a alarms. It will not respond to other models recognised active alarm.
  • Page 7: Limitations

    The Vibrating Alert front of the alarm System will not operate in isolation (on its own), with non Wi- Safe FireAngel smoke or CO alarms CAUTION: Do not put the Vibrating Alert or any alarms made by other manufacturers. Your...
  • Page 8 Always test to ensure the entire Wi-Safe Home Safety System (all alarms and receivers) is still working The FireAngel Wi-Safe Home Safety System may after any changes to your building’s structure, not alarm before a fire causes damage, injury or...
  • Page 9 of CO. WHEN THIS OCCURS YOU MUST RESTORE POWER WITHIN 3 DAYS TO RECHARGE The Vibrating Alert System requires both a continuously powered AC electrical supply and THE BACKUP BATTERY AND MAINTAIN CORRECT OPERATION. internal battery for its normal operation. The battery accompanying this product is rechargeable The Vibrating Alert System is designed to alert and charges when there is mains power to the...
  • Page 10 sufficient time to alert you of the danger and lethal electric shock provide adequate time for your escape. In order • Impair its operation to maximise your level of safety, always test your • Invalidate your warranty Vibrating Alert System by testing all alarms in DANGER: Under no circumstances the Wi-Safe system every week to ensure the whole system is in full working order and that should this product be immersed in...
  • Page 11: Vibrating Alert System

    Remove clear protective wrapper or insulation HOW TO INSTALL YOUR tape from battery terminals prior to installation. VIBRATING ALERT SYSTEM Remove the battery cover from the back of the Receiver Box. Preparation Press arrow on drawer IMPORTANT: Make sure you have read and in and slide out to reveal battery understood this entire manual before installing...
  • Page 12: Installation

    the yellow LED will do one of the following: Installation i) If the battery has discharged completely during We recommend wall mounting the Receiver Box. shipping the yellow LED will flash twice every To do this drill two holes 64mm apart, centre to 5 seconds to indicate that the battery level is centre, using the guide below (Warning - make low.
  • Page 13: Location Of The Vibrating Pad

    Location of the Vibrating Pad Connecting to Wi-Safe Alarms Your Vibrating Alert System is designed to respond Position the Vibrating Pad in its required position. to smoke and carbon monoxide alarms that have a Hook the Receiver Box onto the screws Wi-Safe interconnect function.
  • Page 14 has been opened out, push the learn button pressed again, which will switch off learn mode. located in the hole on the side of the Receiver Box briefly and release. The learn mode LED sequence shows that your On releasing the button the Yellow and Red LEDs Vibrating Alert System is waiting for alarm signals on the front of the Handset will illuminate one to be learnt.
  • Page 15: Testing

    smoke alarm test cycle is complete the yellow and system, you should press the learn button on the red LEDs on the Receiver Box will flash rapidly Receiver Box once to stop the learn mode. The again in the normal ‘learn mode LED sequence’. ‘learn mode LED sequence’...
  • Page 16 people to carry this out. Ensure that your Receiver that the red LED on the Receiver Box flashes for Box and Vibrating Pad is located in its most suitable a short time (the time that the CO alarm is in its position (refer to section on ‘’Positioning’’, page 5), test cycle i.e.
  • Page 17: Operation

    OPERATION A On Standby with AC power connected B In Alarm WCO-628 Smoke Detected CO Detected POWER POWER POWER FAULT FAULT FAULT ALARM ALARM ALARM POWER POWER POWER POWER FAULT FAULT FAULT FAULT ALARM ALARM ALARM ALARM LED status on Receiver Box ‘Alarm’...
  • Page 18 2 second pause, this pattern will continue until Vibrating Alert System Basic the smoke alarm stops sending a signal. Function For CO alarms: When a signal is detected A On Standby with AC power connected from a Wi-Safe carbon monoxide alarm the The Receiver Box should be connected to an red LED will flash 4 times rapidly followed AC supply and the Vibrating Pad should be...
  • Page 19: Removal Of Ac Mains Power

    Monoxide. You will only be able to silence the of 3 days. Vibrating Alert System by silencing the alarm that initially triggered the system. Battery Care NOTE: The CO alarm can only be silenced The battery must be in good condition to provide if the alarm was caused by low levels of CO adequate backup power in the event that AC being detected ie.
  • Page 20: System Integrity Check

    WARNING: Use only the battery • Changing the battery in any alarm in the included in this packas it has been system chosen specifically for this application. Use of • Changing the layout of your house (ie. other batteries may damage the product. structural changes, moving large items of furniture, wiring changes, major decorative The battery provided is rechargeable and alterations, adding large metal constructions) is continuously charged when plugged into • Installation of electronic equipment...
  • Page 21: Low Battery

    Power (See “Basic Function” section). Green LED permanently illuminated. In normal Carbon Monoxide conditions (AC (mains) power connected), this is continuously illuminated to indicate that the Red ALARM LED. Flashing red LED when a Carbon Vibrating Alert System is powered by the AC Monoxide alarm in the system is in “alarm”...
  • Page 22: What To Do If Your Wi-Safe

    a remote signal from a carbon monoxide (CO) WHAT TO DO IF YOUR alarm the red ALARM LED on the receiver box VIBRATING ALERT SYSTEM will flash 4 times rapidly followed by a pause. ALARMS This cycle will continue while the CO alarm is in alarm.
  • Page 23 following rules with your children each time you • Call the fire service on 999 as soon as possible have a fire drill. This will help everyone remember from outside your house. If possible use a them in case of a real emergency. neighbour’s phone or call box rather than a mobile phone (as the location can be traced • Don’t panic;...
  • Page 24 from fires and how to plan your family’s escape. LEVEL ALARM. Ensure that you know what actions to take in the event of both high and low-level alarms. What to do In the Event of a Carbon Monoxide Alarm What To Do During A High-Level Alarm Sounding • Keep calm and open the doors and windows to ventilate.
  • Page 25 • Do not re-enter the property until the alarm icon by pressing the Test/Reset button. has stopped. • Do not use the appliance again until it has • Get medical help immediately for anyone been checked by an expert. In the case of gas suffering the effects of carbon monoxide appliances this must be a CORGI registered poisoning, (headache, nausea), and advise that installer.
  • Page 26: Repair

    If your Vibrating Alert System is not operating properly, see “Troubleshooting Chart” on pages 26 & 27. If you cannot solve the problem, please call the FireAngel Technical Support Line for advice on 024 7623 6663 or visit the ‘Support’ section on our website www.fireangel.co.uk If your Vibrating Alert System is no longer under warranty, replace it immediately.
  • Page 27: Troubleshooting

    TROUBLESHOOTING Problem Solution Upon connection of the This is normal if the battery capacity has become very low in transit. Switch the AC (mains) power on to charge the rechargeable rechargeable battery the yellow LED flashes twice battery. The yellow LED may continue to flash twice every 5 every 5 seconds seconds for up to 72 hours (until the battery is sufficiently charged).
  • Page 28 The Vibrating Alert System Ensure that the smoke/CO alarm is working and does not have a does not respond to an alarm low battery. that is being tested. Check that the alarm is compatible (check for the Wi-Safe logo) and has been connected to the Vibrating Alert System (see “How to Install your Vibrating Alert System - 5 Connecting to Wi-Safe Alarms”, page 12).
  • Page 29: Disposal

    Provided it is returned with apply. postage prepaid and proof of purchase date, FireAngel Ltd hereby warrants that during the 5 The battery should be disconnected before (five) year period commencing from the date of disposal. You can also return your Vibrating Alert purchase FireAngel Ltd, at its discretion, agrees to System for disposal.
  • Page 30: Returns

    This warranty applies to the Except for death or personal injury, FireAngel shall original retail purchaser from the date of original not be liable for any loss of use, damage, cost or retail purchase and is not transferable. Proof of expense relating to this product or for any indirect purchase is required.
  • Page 31: Products In The Wi-Safe Range

    Wi-Safe Product Range suitable for use with WVP- date of purchase to: 626 Wi-Safe Vibrating Alert System • Wi-Safe Optical Smoke Alarm WSO-601 FireAngel Limited • Wi-Safe Ionisation Smoke Alarm WSI-601 The TechnoCentre • Wi-Safe 10 Year Optical Smoke Alarm WSO- Puma Way Coventry CV1 2TT • Wi-Safe 10 Year Ionisation Smoke Alarm WSI-...
  • Page 32 Technical Support Line 024 7623 6663 Text phone users dial 18001 024 7623 6663 Eire dial 1-800 523171 E-mail: technicalsupport@fireangel.co.uk Web: www.fireangel.co.uk FireAngel Ltd. The Technocentre, Puma Way, Coventry CV1 2TT England GN0068/R2...