Power modules

AC power module
AC in LED
DC out LED
Error LED
Power module LEDs: Each power module has three LEDs to indicate the status of
the power module.
v AC (or DC) in: When continuously lit, this green LED indicates that the input
power source is working. If the LED is not lit, it indicates that the input power
source is not present or is incorrect.
v DC out: When continuously lit, this green LED indicates that the output power is
present. If the LED is not lit, it indicates that the output power is not present.
v ! (Error): When continuously lit, this amber LED indicates that there is a error
condition within the power module.
Table 3. Power module LEDs
DC IN or AC IN
DC OUT
On
On
On
Off
DC power module
! (Error)
(amber)
Description and action
Off
The power module is on and operating
correctly.
Off or On*
There is an output power problem. A system
error has shut down the power module.
Actions: Determine the cause of the shutdown
using the diagnostics and replace the failed
component. When the fault has been cleared,
reset the power module in one of the following
ways:
v Issue a power-module reset through the
management module.
v Remove the power module from the unit for
at least 10 seconds.
If the problem remains, have the unit serviced.
*Error LED will operate only if a redundant
power supply is installed.
DC in LED
DC out LED
Error LED
Chapter 1. General information