3-6 Compaq 64-Bit/66 MHz Single Channel Wide Ultra3 SCSI Adapter Installation Guide

SCO UnixWare 7.x

SCO OpenServer 5

Use the following instructions to install the driver on a system already running
UnixWare 7.xx. The driver file, named ADST70, is located on the UnixWare
7.xx EFS diskette containing HBA drivers.
NOTE: Compaq Extended Feature Supplement (EFS) version 7.xx or later for SCO
UnixWare 7.x is required for operation with the Compaq 64-Bit/66 MHz Single Channel
Wide Ultra3 SCSI Adapter.
1. Start the system and log in with root privileges.
2. Insert the Compaq SmartStart and Support Software CD into the CD
drive.
3. Select Compaq SCO UnixWare 7.x EFS on the Diskette Builder screen
and create the diskettes for EFS version 7.xx or later.
4. Use the SCO PKGADD utility to install the Compaq EFS from the
diskettes. Online documentation is included on the EFS diskettes. The
driver name is ADST70.
5. Insert the diskette created with EFS drivers labeled HBA into the
diskette drive.
6. At the Unix command line, enter the following command:
pkgadd -d diskette1 –L
A menu will list all drivers on the diskette.
7. Install the driver by entering the driver number associated with file
name ADST70.
8. Remove the diskette, then type
9. Reboot your system by typing
To install the driver for the 64-Bit/66-MHz Single Channel Wide Ultra3 SCSI
Adapter on a system already running SCO OpenServer 5, you must first create
a set of Compaq Extended Feature Supplement (EFS) diskettes. These
diskettes are then used to install EFS on the system (after removing older EFS
versions, if necessary).
NOTE: Compaq Extended Feature Supplement (EFS) version 5.36 or later for SCO
OpenServer 5 is required for operation with the Compaq 64-Bit/66 MHz Single Channel
Wide Ultra3 SCSI Adapter.
to quit.
q
init 6.