Fc Connection Blade - Fujitsu PRIMERGY B900 Reference Manual

Blade server systems, contents of the mmb s1 help system
Table of Contents

Advertisement

(Memory, USB or Local File).
Memory/USB Backup Files: Here you can select the version which you
o
wish to restore from all the versions which have been backed up so far.
Local Backup Files: Offers you the option of searching for particular
o
versions which have been backed up in local files.
Restoration Status: After you have clicked the "Restore" button, the
o
status is displayed here. After restoration has been completed, you can
click the "Refresh Status" button to return to the default status "Not
Started".
View Configuration: Displays the current interface data between the
o
MMB and the connection blade.

FC Connection Blade

Information
Blade Information
Manufacturer: Displays manufacturer information.
o
Date Manufactured: Displays the production date.
o
Serial Number: Displays the serial number.
o
Product Name: Displays the product name.
o
Product Number: Displays the product number.
o
Hardware Version: Displays the board version.
o
Firmware Version: Displays the management firmware version.
o
Management Port MAC Address: Displays the MAC address.
o
WWN Address: Displays the WWN address for FC connection blade.
o
Firmware Mode: Displays the firmware mode. "8Gb FC Connection
o
Blade-x" can have the values "Access Gateway", "Native" or "Interop".
The mode can be set via the connection blade's built-in command line
interface or via the "Configuration" tab, "Firmware Mode Settings".
Afterwards the blade has to be rebooted or reboots automatically.
Administrative URL: URL to link the connection blade's web home
o
page.
Power Management
Power Settings: The user can reset the blade after selecting the power action and
clicking the "Apply" button.
Configuration
The current status of some parameters is queried using the "Refresh" button. This is
necessary as the parameters can also be changed via the connection blade's own
management functions. If no change is displayed after the button has been pressed, this
means that the parameter has not been changed by the connection blade up to this point
in time.
User Assigned Name: Enter the connection blade's user assigned name.
The user assigned name may not be longer than 31 characters and must start
with a letter that can be followed by letters, digits, and hyphens ("-"). Changing
the rack name (via the menu item "System Unit" in the Web UI) may overwrite