To manually add the pack-specific UBA parameters to the
12-f. Open a second terminal emulator.
12-g. On the DataChannel server, change your working directory to the
directory (
/opt/datachannel/conf
cd DATA_CHANNEL_HOME
12-h. Make a backup copy of the
cp dc.cfg dc.cfg.ORIG
12-i. In a text editor, open the
12-j. Search for the UBA parameters, which begin with the string
file when you configured the UBA Bulk Collector and installed the DataChannel
dc.cfg
configuration, as described in the Netcool/Proviso Installation Guide.
12-k. Copy the pack-specific UBA parameters from the
to the
dc.cfg
12-l. When you are satisfied with your edits, do the following:
— Quit the
— Write and quit the
13. Load the DataChannel environment.
In subsequent steps, you will execute
the shell with the DataChannel environment by following these steps:
13-a. Log in to the DataChannel server as pvuser.
13-b. Change your working directory to the DataChannel home directory (
default), using the following command:
cd /opt/datachannel
13-c. Load the shell with the DataChannel environment, by sourcing the
follows:
. /opt/datachannel/dataChannel.env
14. Restart the DataChannel to activate the UBA and read in changes to
14-a. Open a terminal emulator on the DataChannel server.
14-b. Use the
dccmd
dccmd -action stop all
14-c. Use the
dccmd
dccmd -action forget all
14-d. Use the following command to find the process identifiers (pids) associated with the DataChannel
visual processes:
DATA_CHANNEL_HOME/bin/findvisual
where:
DATA_CHANNEL_HOME
14-e. Use the following commands to stop each DataChannel visual process:
kill -9 <cnsw_pid>
kill -9 <logw_pid>
450
, by default), by entering the following command:
/conf
file, by entering the following command:
dc.cfg
file for editing.
dc.cfg
file.
voip_cisco_ipt_sample_dc.cfg
file.
dc.cfg
commands. To ensure that you can run these commands, load
dccmd
command to stop all DataChannel applications:
command to release all daemons running in the DataChannel:
is
/opt/datachannel
Netcool/Proviso Cisco IP Telephony Technology Pack User's Guide, Version 4.3-W
file, follow these steps:
dc.cfg
DATA_CHANNEL_HOME/conf
. These parameters were written to the
UBA
voip_cisco_ipt_sample_dc.cfg
template file.
/opt/datachannel
dataChannel.env
.
dc.cfg
, by default.
template file
, by
file, as