PRODUCT IDENTIFICATION

The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
S
Brand Name
G: Goodman
(Standard Feature Set Models)
S: Goodman
(High Feature Set Models)
Product Family
S: Split System
Product Type
C: Condenser R-22
X: Condenser R-410A
H: Heat Pump R-22
Z: Heat Pump R-410A
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
2
S Z
16
SEER
SEER Rating

HIGH VOLTAGE!

Disconnect ALL power before servicing or installing this unit. Multiple
power sources may be present. Failure to do so may cause property
damage, personal injury or death.
Installation and repair of this unit should be performed ONLY by individu-
als meeting the requirements of an "entry level technician" as specified
by the Air Conditioning and Refrigeration Institute (ARI). Attempting to
install or repair this unit without such background may result in product
damage, personal injury or death.
Goodman will not be responsible for any injury or property damage arising
from improper service or service procedures. If you install or perform
service on this unit, you assume responsibility for any personal injury or
property damage which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
036
1
Electrical
1: 208/230V/60Hz/1ph
3: 208/230V/60Hz/3ph
4: 460V/60Hz/3ph
Nominal Capacity
024: 2 tons
036: 3 tons
048: 4 tons
060: 5 tons
A
A
Minor Revision
A: Initial Release
Major Revision
A: Initial Release