Goodman PH 15 SEER Series Technical Manual
Goodman PH 15 SEER Series Technical Manual

Goodman PH 15 SEER Series Technical Manual

Multi position package heat pump units with r410a

Advertisement

Quick Links

TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
*PH 15 SEER Multi Position
Refer to Service Manual RS6300008 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not
assume any responsibility for property damage or personal injury due to improper service procedures or
services performed by an unqualified person.
Package Heat Pump Units
with R410A
Copyright © 2010 - 2012 Goodman Manufacturing Company, L.P.
AL
AL
AL
AL
RT6332010r9
June 2012

Advertisement

loading
Need help?

Need help?

Do you have a question about the PH 15 SEER Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Goodman PH 15 SEER Series

  • Page 1 • Models listed on page 3. RT6332010r9 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not June 2012 assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Installation and repair of this unit Goodman will not be responsible WARNING WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    PRODUCT DESIGN *PH15 models APH15 models *PH15 (M Series) Package Units are designed for outdoor The outdoor fan motors are single phase capacitor type mo- tors on the APH15 models. APH15 units have ECM indoor installations only in either residential or light commercial ap- blower motors that are energized by a low voltage signal from plications and are available in 2, 2.5, 3, 3.5, 4 &...
  • Page 5 PRODUCT DESIGN Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. The ZPS modulated scroll uses a single step of unloading to go from full capacity to approximately 67% capacity. A single speed, high efficiency motor continues to run while the scroll modulates between the two capacity steps.
  • Page 6 PRODUCT DESIGN *PH15[24-60]M41* HKR ELECTRICAL DATA Circuit #1 Circuit #2 Maximum Maximum Actual Minimum Circuit Minimum Circuit kW & BTU Overcurrent Overcurrent Ampacity Ampacity at 240V Protection (amps) Protection (amps) at 208 / 240V at 208 / 240V at 208 / 240V at 208 / 240V *PH1524M41* / *A HKR05A,CA...
  • Page 7: Product Dimensions

    PRODUCT DIMENSIONS *PH15[24-60]M41* POWER WIRE ENTRANCE 4 1/8 2 1/8 1 3/8 5 ½ 6 ½ 2 34 RETURN SUCTION/LIQUID PRESSURE PORT SUPPLY CONDENSATE DRAIN CONTROL 18 7/8 CONNECTION WIRE 3/4” NPT FEMALE ENTRANCE BLOWER ACCESS PANEL MEDIUM CHASSIS *PH1524M41* *PH1530M41* *PH1536M41* LARGE CHASSIS...
  • Page 8 PACKAGE HEAT PUMP SPECIFICATIONS GPH15[24-36]M41A* GPH1524M41 GPH1530M41 GPH1536M41 GPH1524M41* GPH1530M41* GPH1536M41* COOLING COOLING CAPACITY, BTUH 24,000 24,000 29,000 29,000 35,400 35,400 CAPACITY SEER / EER 15.0 / 11.3 15.0 / 11.3 14.5 / 11.5 14.5 / 11.5 14.5 / 11.5 14.5 / 11.5 HEATING BTU/h (47°)
  • Page 9 PACKAGE HEAT PUMP SPECIFICATIONS GPH15[43-60]M41AB/C/D GPH1549M41 GPH1549M41 GPH1560M41 GPH1560M41 GPH1543M41* AB/AC AB/AC COOLING COOLING CAPACITY, BTUH 40,000 46,000 46,000 55,500 55,500 CAPACITY SEER / EER 15.0 / 12.0 15.0 / 11.7 15.0 / 11.7 14.0 / 10.3 14.0 / 10.3 HEATING BTU/h (47°) 39,000...
  • Page 10 PACKAGE HEAT PUMP SPECIFICATIONS APH15[24-36]M41A* APH 1524M41 APH 1530M41 APH 1536M41 APH1524M41* APH1530M41* APH1536M41* COOLIN G C OOLING C APACITY, BTUH 24,000 24,000 29,000 29,000 35,400 35,400 CAPACITY SEER / EER 15.0 / 12.0 15.0 / 12.0 14.5 / 11.5 14.5 / 11.5 14.5 / 11.5 14.5 / 11.5...
  • Page 11 PACKAGE HEAT PUMP SPECIFICATIONS APH15[43-60]M41AB/C/D APH1549M41 APH1549M41 APH1560M41 APH1560M41 APH1543M41* AB/AC AB/AC COOLING COOLING CAPACITY, BTUH 40,000 46,000 46,000 55,600 55,600 SEER / EER 15.0 / 12.0 15.0 / 11.7 15.0 / 11.7 14.0 / 10.3 14.0 / 10.3 CAPACITY HEATING BTU/h (47°) 39,000...
  • Page 12 Internal Filter Rack, Medium Chassis GPH13MFR103 Internal Filter Rack, Large Chassis GPGHFR101-103 External Horizontal Filter Rack for Goodman/Amana Gas/Electric and Multi-position Package Units All Chassis SQRPG101/102 Square to Round Adapter w/ 16" Round Downflow Application, Medium Chassis SQRPG103 Square to Round Adapter w/ 18" Round Downflow Application, Large Chassis SQRPGH101/102 Square to Round Adapter w/ 16"...
  • Page 13: Blower Performance Data

    GPH15[24-60]M41* BLOWER PERFORMANCE DATA Dry Coil Data E.S.P (In. of H Model Speed Volts T1 (G) WATTS T2 / T3 (W2) WATTS 1058 1012 T4 / T5 (Y) WATTS T1 (G) WATTS 1132 1070 1011 T2 / T3 (W2) WATTS 1287 1236 1165...
  • Page 14 APH15[24-60]M41* BLOWER PERFORMANCE DATA Evaporator Blower Specifications with ECM Motors APH1524M41 APH1530M41 Cooling/HP Adjust Electric Adjust Cooling/HP Adjust Electric Adjust CFM* CFM* CFM* CFM* Speed Heat Speed Heat Minus Minus Minus Minus Normal Normal Normal Normal Plus Plus Plus Plus Minus Minus Minus...
  • Page 15 APH15[24-60]M41* BLOWER PERFORMANCE DATA Dipswtich Settings Speed Cooling/HP Speed Electric Heat Model Switch 5 Switch 6 Model Switch 1 Switch 2 1050 1050 APH1524 APH1524 1250 1250 1,100 1,100 APH1530 APH1530 1,000 1,000 1250 1250 1100 1100 APH1536 APH1536 1000 1000 1800 1800...
  • Page 16 BLOWER PERFORMANCE DATA...
  • Page 17 COOLING PERFORMANCE DATA *PH1524M41*...
  • Page 18 COOLING PERFORMANCE DATA *PH1524M41*...
  • Page 19 COOLING PERFORMANCE DATA *PH1530M41*...
  • Page 20 COOLING PERFORMANCE DATA *PH1530M41*...
  • Page 21 COOLING PERFORMANCE DATA *PH1536M41*...
  • Page 22 COOLING PERFORMANCE DATA *PH1536M41*...
  • Page 23 COOLING PERFORMANCE DATA *PH1543M41*...
  • Page 24 COOLING PERFORMANCE DATA *PH1543M41*...
  • Page 25 COOLING PERFORMANCE DATA *PH1549M41* LOW STAGE -...
  • Page 26 COOLING PERFORMANCE DATA *PH1549M41* LOW STAGE -...
  • Page 27 COOLING PERFORMANCE DATA *PH1549M41* HIGH STAGE -...
  • Page 28 COOLING PERFORMANCE DATA *PH1549M41* HIGH STAGE -...
  • Page 29 *PH1560M41* COOLING PERFORMANCE DATA LOW STAGE -...
  • Page 30 COOLING PERFORMANCE DATA *PH1560M41* LOW STAGE -...
  • Page 31 *PH1560M41* COOLING PERFORMANCE DATA HIGH STAGE -...
  • Page 32 COOLING PERFORMANCE DATA *PH1560M41* HIGH STAGE -...
  • Page 33: Heating Performance Data

    HEATING PERFORMANCE DATA *PH15[24-43]M41* EXPANDED PERFORMANCE DATA MODEL: *PH1524M41* HEATING OPERATION Outdoor Ambient Temperature 29.4 27.8 26.2 24.5 23.4 22.7 21.1 19.4 15.6 14.4 13.2 12.5 12.0 10.8 Delta T 31.7 30.0 28.2 26.4 25.2 24.4 22.7 20.9 16.8 15.5 14.3 13.5 13.0...
  • Page 34 HEATING PERFORMANCE DATA *PH15[49-60]M41* EXPANDED PERFORMANCE DATA MODEL: *PH1549M41* LOW STAGE HEATING OPERATION Outdoor Ambient Temperature 40.0 37.8 35.6 33.3 31.8 30.8 28.6 26.4 21.8 20.1 18.5 17.5 16.9 15.1 13.4 11.7 10.0 Delta T 30.8 29.2 27.5 25.7 24.5 23.8 22.1 20.4...
  • Page 35: Wiring Diagrams

    GPH15[24-36, 43]M41AB/C WIRING DIAGRAMS SEE NOTE 8 SEE NOTE 3 SEE NOTE 7 YL/PK SEE NOTE 5 C-RV R-PS1 O-RV LVDR LVJB HVDR R-DFT RCCF SEE NOTE 4 NO E BL PK CONTROL RD RD C L G N 1 2 3 COMP SEE NOTE 2 SUPPLY VOLTAGE...
  • Page 36 WIRING DIAGRAMS GPH15[24-36, 43]M41AC Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 37 WIRING DIAGRAMS GPH15[42, 49-60]M41AB/D SEE NOTE 7 SEE NOTE 3 SEE NOTE 6 YL/PK YL/PK SEE NOTE 8 LVJB RCCF BL/PK BL/PK SEE NOTE 4 C L G N SEE NOTE 5 1 2 3 COMP SEE NOTE 2 SEE NOTE 5 COMPONENT LEGEND FACTOR Y W IRING LINE VOLTAGE...
  • Page 38 GPH15[42, 49-60]M41AB/D WIRING DIAGRAMS Applies to GPH1549M41AC (serial number 1205184221 & prior) & GPH1560M41AC (serial number 1205184196 & prior). Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 39 WIRING DIAGRAMS GPH15[49-60]M41AC/D Applies to GPH1549M41AC (serial number 1205184222 & later) & GPH1560M41AC (serial number 1205184197 & later). Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 40 WIRING DIAGRAMS APH15[24-36, 43]M41AB SEE NOTE 8 SEE NOTE 7 YL/PK SEE NOTE 4 C-RV R-PS1 NOTE 5 LVJB O-RV LVDR HVDR R-DFT RCCF SEE NOTE 3 CONTROL RD RD BL/PK COMP 16 PIN PLUG SUPPLY VOLTAGE 208-240/1/60 COMPONENT LEGEND FACTORY WIRING CONTACTOR LINE VOLTAGE...
  • Page 41 WIRING DIAGRAMS APH15[24-36, 43]M41AB/AC SEE NOTE 8 SEE NOTE 8 SEE NOTE 2 SEE NOTE 2 SEE NOTE 7 SEE NOTE 7 YL/PK YL/PK YL/PK YL/PK SEE NOTE 4 SEE NOTE 4 NOTE 5 NOTE 5 LVDR 0-RV LVJB LVJB C-RV HVDR RCCF...
  • Page 42 WIRING DIAGRAMS APH15[42, 48-60]M41AB SEE NOTE 9 SEE NOTE 2 SEE NOTE 8 SEE NOTE 4 YL/PK C-RV NOTES R-PS1 5 & 6 LVJB O-RV LVDR HVDR R-DFT RCCF SEE NOTE 3 CONTROL NOTE 7 BL/PK RD RD 16 PIN COMP PLUG FACTORY WIRING...
  • Page 43 APH15[42, 49-60]M41AB/C/D WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.