C
C
: 35,000 - 56,500 Btu/
ooling
ApACity
H
C
: 33,600 - 56,400 Btu/
EAting
ApACity
Standard Features
• R-410A chlorine-free refrigerant
• Two-Stage Copeland® UltraTech scroll compressor
• High-density foam compressor sound blanket
• ComfortNet™ Communications System compatible
• Expanded ComfortAlert diagnostics built in
• Set-up capable with two low-voltage wires
to outdoor unit
• Diagnostic indicator lights and storage of six fault codes
• Color-coded terminal strip for non-communicating set-up
• SmartShift™ technology with short-cycle protection
to ensure quiet, reliable defrost
• Factory-installed bi-flow liquid line filter drier
• Factory-installed suction line accumulator
• Factory-installed compressor crankcase heater
• Factory-installed high-capacity muffler
• Factory-installed coil and ambient temperature sensors
• High- and low-pressure switches
• Fully charged for 15' of tubing length
• Quiet ECM-style condenser fan motor
• Sweat connection service valves with easy access
to gauge ports
• AHRI Certified; ETL Listed
Cabinet Features
• Goodman® brand sound control top design
• Wire fan discharge grille
• Steel louver coil guard
• Baked-on powder paint finish
• Rust-resistant coated screws
• Compact footprint
• Top and side maintenance access
• Single panel access to controls with space
provided for field-installed accessories
• When properly anchored, meets the 2001 Florida Building
Code unit integrity requirements for hurricane-type winds
(Anchor bracket kits available.)
* Complete warranty details available from your local dealer or at www.goodmamfg.com. To receive the Lifetime Compressor Limited Warranty (good for as long as you own
your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online
registration is not required in California or Québec.
SS-DSZC18
H
H
Contents
Nomenclature .................................................................... 2
Product Specifications ....................................................... 3
Expanded Cooling Data ..................................................... 4
Expanded Heating Data . .................................................. 20
AHRI Ratings . ....................................................................22
Dimensions .....................................................................30
Wiring Diagram . ............................................................... 31
Accessories .......................................................................32
www.goodmanmfg.com
DSZC18
S
S
H
p
plit
yStEm
EAt
18 SEER
up to
R-410A
ump
11/11
Supersedes 5/11

Advertisement

loading

Summary of Contents for Goodman SS-DSZC18

  • Page 1: Table Of Contents

    • Rust-resistant coated screws • Compact footprint • Top and side maintenance access • Single panel access to controls with space provided for field-installed accessories • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * Complete warranty details available from your local dealer or at www.goodmamfg.com. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-DSZC18 plit up to Contents Nomenclature ... 2 Product Specifications ... 3 Expanded Cooling Data ... 4 Expanded Heating Data ..20 AHRI Ratings ..22 Dimensions ...30 Wiring Diagram ..31 Accessories ...32 www.goodmanmfg.com...
  • Page 2: Nomenclature

    460   V ,   3   P hase,   6 0   H z Nominal   C apacity 2   T ons 048         4   T ons 3   T ons 060         5   T ons SS-DSZC18...
  • Page 3 • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. SS-DSZC18 DSZC18 DSZC18...
  • Page 4: Expanded Cooling Data

    RoDuCt pECifiCAtionS — DSZC180361A*/CA*f3743*6**+txV/mBVC1600** — l xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 5 RoDuCt pECifiCAtionS — DSZC180361A*/CA*f3743*6**+txV/mBVC1600** — l xpAnDED ooling tAgE Cont SS-DSZC18 www.goodmanmfg.com...
  • Page 6 RoDuCt pECifiCAtionS — DSZC180361A*/CA*f3743*6**+txV/mBVC1600** — H xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 7 RoDuCt pECifiCAtionS — DSZC180361A*/CA*f3743*6**+txV/mBVC1600** — H xpAnDED ooling tAgE Cont SS-DSZC18 www.goodmanmfg.com...
  • Page 8 RoDuCt pECifiCAtionS — DSZC180481A*/CA*f3743*6**+txV/mBVC2000** — l xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 9 — DSZC180481A*/CA*f3743*6**+txV/mBVC2000** — l xpAnDED ooling SS-DSZC18 www.goodmanmfg.com RoDuCt pECifiCAtionS tAgE Cont...
  • Page 10 RoDuCt pECifiCAtionS — DSZC180481A*/CA*f3743*6**+txV/mBVC2000** — H xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 11 RoDuCt pECifiCAtionS — DSZC180481A*/CA*f3743*6**+txV/mBVC2000** — H xpAnDED ooling tAgE Cont SS-DSZC18 www.goodmanmfg.com...
  • Page 12 RoDuCt pECifiCAtionS — DSZC180601A*/CA*f3743*6**+txV/mBVC2000** — l xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 13 — DSZC180601A*/CA*f3743*6**+txV/mBVC2000** — l xpAnDED ooling SS-DSZC18 www.goodmanmfg.com RoDuCt pECifiCAtionS tAgE Cont...
  • Page 14 RoDuCt pECifiCAtionS — DSZC180601A*/CA*f3743*6**+txV/mBVC2000** — H xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 15 RoDuCt pECifiCAtionS — DSZC180601A*/CA*f3743*6**+txV/mBVC2000** — H xpAnDED ooling tAgE Cont SS-DSZC18 www.goodmanmfg.com...
  • Page 16 RoDuCt pECifiCAtionS — DSZC180601B / CApf4961D6*+txV / mBVC2000A — l xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 17 RoDuCt pECifiCAtionS — DSZC180601B / CApf4961D6*+txV / mBVC2000A — l xpAnDED ooling tAgE Cont SS-DSZC18 www.goodmanmfg.com...
  • Page 18 RoDuCt pECifiCAtionS — DSZC180601B / CApf4961D6*+txV / mBVC2000A — H xpAnDED ooling tAgE www.goodmanmfg.com SS-DSZC18...
  • Page 19 RoDuCt pECifiCAtionS — DSZC180601B / CApf4961D6*+txV / mBVC2000A — H xpAnDED ooling tAgE Cont SS-DSZC18 www.goodmanmfg.com...
  • Page 20: Expanded Heating Data

    2.89 2.66 2.42 2.17 1.90 1.61 20.9 18.7 16.6 14.5 12.4 10.1 16.1 14.5 12.8 11.2 2.26 2.19 2.13 2.07 2.01 1.95 2.71 2.50 2.28 2.05 1.80 1.52 Amps = Outdoor unit amps (comp.+fan) kW = Total system power SS-DSZC18...
  • Page 21 3.68 14.6 14.1 13.6 13.0 12.6 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature SS-DSZC18 Outdoor Ambient Temperature 55.2 51.3 47.3 46.7 43.1 39.7 37.5...
  • Page 22: Ahri Ratings

    35,000 20,000 4586494 35,000 20,000 4415239 35,000 20,000 4415238 34,800 20,400 4415237 35,000 20,400 4415205 35,000 20,400 4415204 35,000 20,400 4415203 35,000 20,400 4415202 35,000 20,000 4415201 35,000 20,000 4415200 35,000 20,000 4415199 35,000 20,000 4415198 35,000 20,000 4415197 SS-DSZC18...
  • Page 23 MBE2000**-1B CA*F4961*6A*+TXV MBE1600**-1B* CA*F4961*6D*+TXV A*VC950915DXA* CA*F4961*6D*+TXV A*VC950714CXA* CA*F4961*6D*+TXV G*VC951155DXA* CA*F4961*6D*+TXV G*VC950915DXA* CA*F4961*6D*+TXV G*VC950905DXA* CA*F4961*6D*+TXV G*VC950905CXA* See Notes on Page 26. SS-DSZC18 Cooling Capacity (BTU/h) TVA Ratings³ Total Sens. EER² SEER¹ Total Sens. 34,600 26,300 12.5 17.5 32,200 26,100 35,000 26,600 13.0...
  • Page 24 35,000 20,000 3654811 35,000 20,400 3654810 35,000 20,000 3654809 35,000 20,000 3654808 35,000 20,000 3654807 35,000 20,000 3654806 35,000 20,000 3654805 35,000 20,000 3654804 35,000 20,000 3654803 35,000 20,000 3654802 35,000 20,000 4594729 35,000 20,000 4586499 35,000 20,000 4184955 SS-DSZC18...
  • Page 25 A*VC80704BXA* CSCF3642N6C*+TXV A*V81155C** CSCF3642N6C*+TXV A*V80905C** CSCF3642N6C*+TXV A*V80704B** CSCF3642N6C*+TXV MBVC1600**-1A* CSCF3642N6C*+TXV MBE1600**-1B* CSCF4860N6C*+TXV A*VC950915DXA* CSCF4860N6C*+TXV A*VC950714CXA* See Notes on Page 26. SS-DSZC18 Cooling Capacity (BTU/h) TVA Ratings³ Total Sens. EER² SEER¹ Total Sens. 35,000 26,600 12.8 18.0 32,600 26,400 34,600 26,300 12.5...
  • Page 26 47,000 29,000 4184958 47,000 29,000 4184868 47,000 29,000 3654897 47,000 29,000 3654896 47,000 29,000 3654895 47,000 29,000 3654894 47,000 29,000 3654893 47,000 29,000 3654892 47,000 29,000 3654891 47,000 29,000 3654890 47,000 29,000 3654889 47,000 29,000 3654888 47,000 29,000 3654887 SS-DSZC18...
  • Page 27 A*V81155C** CSCF4860N6C*+TXV A*V80905C** CSCF4860N6C*+TXV MBVC2000**-1* CSCF4860N6C*+TXV MBE2000**-1B CT*F4860*6A*+TXV MBVC2000**-1* CT*F4860*6A*+TXV MBVC1600**-1A* CT*F4860*6A*+TXV MBE2000**-1B CT*F4860*6A*+TXV MBE1600**-1B* See Notes on Page 29. SS-DSZC18 Cooling Capacity (BTU/h) TVA Ratings³ Total Sens. EER² SEER¹ Total Sens. 47,000 35,300 12.5 17.5 43,700 33,600 47,000 35,300 12.5...
  • Page 28 57,000 35,000 4594739 57,000 35,000 4184963 57,000 35,000 4184873 57,000 35,000 3654956 57,000 35,000 3654955 57,000 35,000 3654954 57,000 35,000 3654953 57,000 35,000 3654952 57,000 35,000 3654951 57,000 36,400 3654950 57,000 36,400 3654949 57,000 36,400 3654958 57,000 36,400 3654957 SS-DSZC18...
  • Page 29 • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay SS-DSZC18 Cooling Capacity (BTU/h) TVA Ratings³...
  • Page 30: Dimensions

    RoDuCt pECifiCAtionS imEnSionS See Notes on Page 26. Model DSZC180361A DSZC180481A DSZC180601A DSZC180601B www.goodmanmfg.com Dimensions W" D" H" 35½ 35½ 38¼ 35½ 35½ 38¼ 35½ 35½ 38¼ 35½ 35½ 38¼ SS-DSZC18...
  • Page 31: Wiring Diagram

    DSZC18 w iRing iAgRAm SS-DSZC18 CONTROL VALVE SOLENOID HIGH/LOW CAPACITY ON/OFF MOTOR CAPACITOR HERM HERM START HARD OPTIONAL COMP www.goodmanmfg.com RoDuCt pECifiCAtionS R C Y1 Y2 W1 O...
  • Page 32: Accessories

    ⁴ Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. DSZC18 DSZC18 www.goodmanmfg.com DSZC18 SS-DSZC18...

This manual is also suitable for:

Dszc180361aDszc180481aDszc180601aDszc180601b