• Models listed on page 3. RT6213005r7 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does November 2011 not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Installation and repair of this unit Goodman will not be responsible WARNING WARNING WARNING...
Page 3
WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
PRODUCT DESIGN These clearances will help avoid air recirculation. If installing SSZ14 models are available in 1 1/2 through 5 ton sizes and two or more units at the same location, allow at least 24 use R-410A refrigerant. They are designed for 208/230 volt inches between units.
HEATING SPECIFICATIONS Model: SSZ140181A* / CA*F3131*6A*+TXV / MBR800**-1 Model: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 Conditions: 600 CFM Indoor Air @ 70°F DB Conditions: 850 CFM Indoor Air @ 70°F DB Basic Unit without Capacity of Unit* Basic Unit without Capacity of Unit* Outdoor Outdoor Auxiliary Heat...
Page 35
HEATING SPECIFICATIONS Model: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1 Model: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1 Conditions: 1400 CFM Indoor Air @ 70°F DB Conditions: 1550 CFM Indoor Air @ 70°F DB Basic Unit without Capacity of Unit* Basic Unit without Capacity of Unit* Outdoor Auxiliary Heat With KW of Auxiliary heat...
Page 36
PERFORMANCE DATA Model: SSZ140361B* / AR*F374316B*+TXV -1 Conditions: 1250 CFM Indoor Air @ 70°F DB Basic U nit without Capacity of U nit* Outdoor Auxiliary Heat With KW of Auxiliary heat Ambient capacity °F. btuh 19.2 c.o.p. 14.4 41.48 4.11 57.86 74.24 90.63...
SSZ140[18,30,42-60]1AA-AE, 241AA-AH, WIRING DIAGRAMS 361AA-AG Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 38
SSZ140[18,30,42-60]1AF, 241AJ, 361AH WIRING DIAGRAMS SSZ140361B* Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 39
SSZ140[18,30,42-60]1AG, 241AK, 361AH WIRING DIAGRAMS SSZ140361B* LVDR 0- RV C-RV HVDR Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.