Goodman SSZ 16 SEER Technical Information Manual

Goodman SSZ 16 SEER Technical Information Manual

Ssz 16 seer split system heat pumps
Hide thumbs Also See for SSZ 16 SEER:

Advertisement

TECHNICAL INFORMATION MANUAL
SSZ 16 SEER
Split System Heat Pumps
Refer to Service Manual RS6200005 for installation, op-
eration, and troubleshooting information.
All safety information must be followed as provided in the
Service Manual.
Refer to the appropriate Parts Catalog for part number
information.
®
This manual is to be used by qualified, professionally trained HVAC techni-
cians only. Goodman does not assume any responsibility for property
damage or personal injury due to improper service procedures or services
performed by an unqualified person.
Copyright © 2006-2007 Goodman Manufacturing Company, L.P.
Models listed
on page 3
RT6214002 Rev. 2
September 2007

Advertisement

Table of Contents
loading

Summary of Contents for Goodman SSZ 16 SEER

  • Page 1 ® This manual is to be used by qualified, professionally trained HVAC techni- RT6214002 Rev. 2 cians only. Goodman does not assume any responsibility for property September 2007 damage or personal injury due to improper service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform...
  • Page 3 Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced...
  • Page 4: Product Design

    PRODUCT DESIGN SSZ16 models are available in 2, 3, 4 and 5 ton sizes and These clearances will help avoid air recirculation. If installing two or more units at the same location, allow at least 24 use R-410A refrigerant. They are designed for 208/230 volt inches between units.
  • Page 5: Specifications

    HEAT PUMP SPECIFICATIONS SSZ160241A* -SSZ160601A* Cooling Capacity, BTUH 24,000 36,000 48,000 60,000 Compressor R.L. Amps 13.4 14.1 19.8 25.6 L.R. Amps 58.3 77.0 109.0 118.0 Low Pressure Switch Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG...
  • Page 6 COOLING PERFORMANCE DATA SSZ160241A*...
  • Page 7 COOLING PERFORMANCE DATA SSZ160241A*...
  • Page 8 COOLING PERFORMANCE DATA SSZ160361A*...
  • Page 9 COOLING PERFORMANCE DATA SSZ160361A*...
  • Page 10 COOLING PERFORMANCE DATA SSZ160481A*...
  • Page 11 COOLING PERFORMANCE DATA SSZ160481A*...
  • Page 12 COOLING PERFORMANCE DATA SSZ160601A*...
  • Page 13 COOLING PERFORMANCE DATA SSZ160601A*...
  • Page 14: Performance Data

    PERFORMANCE DATA SSZ160241A* / CA*F3636*6A*+TXV/ MBE1600**-1 Conditions: 80°F IDB, 67°F IWB @ 875 CFM Outdoor Total Sensible Latent Total Temp. ° F. Btuh Btuh Btuh Watts 75° 25,200 18,540 6,660 1,645 80° 24,900 18,553 6,347 1,697 85° 24,600 18,559 6,041 1,749 90°...
  • Page 15 SPLIT SYSTEM HEATING PERFORMANCE EXPANDED PERFORMANCE DATA MODEL: SSZ160241A* / CA*F3636*6A* + TXV / MBE1600**-1 HEATING OPERATION Outdoor Ambient Temperature 30.2 28.6 26.9 25.1 23.3 21.6 19.9 18.7 17.3 15.9 15.0 14.4 13.0 11.5 10.0 24.0 Delta T 31.9 30.2 28.4 26.6 25.4...
  • Page 16: Heating Specifications

    HEATING SPECIFICATIONS SSZ160241A* / CA*F3636*6A*+TXV/ MBE1600**-1 SSZ160361A* / CA*F4860*6A*+TXV/ MBE2000**-1 Conditions: 875 CFM @ 70°F Indoor Air Conditions: 1200 CFM @ 70°F Indoor Air Basic Unit without Capacity of Unit Basic Unit without Capacity of Unit Outdoor Outdoor Auxiliary Heat With KW of Auxiliary heat Auxiliary Heat With KW of Auxiliary heat...
  • Page 17: Performance Test

    PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
  • Page 18: Wiring Diagrams

    WIRING DIAGRAMS SSZ160[24-48]1A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 19 WIRING DIAGRAMS SSZ160[60]1AA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 20 WIRING DIAGRAMS SSZ160[60]1AB/AC HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

Table of Contents