Voltage Check

With a digital voltage meter or multi-meter to
measure battery voltage.
Voltage:
Fully charged:
13.0 – 13.2V (at 20¢ J )
Undercharged: Below 12.3 V (at 20¢ J )
CHARGING
Connect the Charger positive (+) to the
battery positive (+) terminal.
Connect the Charger negative (-) to the
battery negative (-) terminal.
Charging
current
Charging time
Warning
Strictly keep flames away from a charging
battery.
The charging "ON"/ "OFF" is controlled by
the charger's switch. Do not control the
charging by battery jump wires.
Turn the charger's switch "OFF" at first
before or after charging to prevent from
sparks created on the connectors and
explosion.
To charge a battery must be based on the
battery's ampere-hour showed on label.
CAUTION
Quick charge a battery should be used
only in an emergency.
Make sure the current and charging time
of above description.
The battery will be damaged by too much
current or too rush charging.
When finishing charge, it is necessary to
measure voltage after 30 minutes.
After installing the battery, coat the terminals
with clean grease.
Standard
Max.
0.6A
6.0A
5~10H
1H
16. ELECTRICAL EQUIPMENT