16. ELECTRICAL EQUIPMENT

Battery

Removal
Remove the battery cover.
CAUTION
Electrolyte (diluted sulfuric acid) is very
toxic. Once it spreading on clothes,
skin, or eyes, it will cause burned or
blind. In case of being spread, flush
with great quantity of water immediately,
and then send to hospital.
When clothes is spread by electrolyte, it
will contact with skin. So, it must flush
with great quantity water to take off the
clothes.
Remove the battery cover.
Disconnect the negative (-) cable from the
battery first, then the positive (+) cable.
Remove the battery.
Install the battery in reverse order of
removal.
CAUTION
To prevent form circuit short, connect
positive(+) terminal at first, and next
negative (-) terminal.
16-6
Battery cover
Negative cable (-)
Fuse box
positive (+)
SYM
Positive cable (+)
negative (-)