CHARGING SYSTEM

Charging wire diagram

yellow
alternator

Current Leakage Inspection

Turn the main switch to OFF position, and
remove the negative cable terminal (-) from
the battery.
Connect an ammeter between the negative
cable terminal and the battery negative
terminal (as shown on left diagram).
Caution
In the current leakage test, set the current
range at larger scale, then gradually
decrease to the lower scale as the test
process goes to avoid possible damage to
the ammeter and the fuse.
Do not turn the main switch to "ON"
position during test.
If the leaked current exceeds the specified
value, it may indicate a short circuit.
Allowable current leakage: Less than 1
mA.
Disconnect each cable one by one and take
measurement of the current of each cable to
locate the short circuit.
white
REG.REC.
green/black
5
Auto
5
by-starter
16. ELECTRICAL EQUIPMENT
green
fuse(10A
)
red
red
battery
W
ground
wire
green
green
Battery(-) terminal
16-5