Page 2
Signal Communications Limited. TeleEye is a trademark of Signal Communications Limited and is registered in China, European Communities, Hong Kong, US and other countries. All other trademarks are the property of their respective owners.
Table of content SECTION 1 ................................1 .................................1 NTRODUCTION Introduction ...............................1 Features..............................1 Package Contents ............................1 Front panel description ..........................2 Rear panel description ..........................2 SECTION 2 ................................3 ................................3 NSTALLATION Install Hard Disk ............................3 Remove Hard Disk.............................4 Mobile data modem installation ........................5 Wireless LAN adaptor installation......................6 Mount to vehicle ............................6 Video installation............................8...
By connecting TeleEye RX504 to a mobile data modem, the driver can push a button to trigger the TeleEye RX504 to send an alarm and seamless video back to the central monitoring station via mobile networks such as HSDPA, UMTS, EDGE or GPRS in an emergency situation.
TeleEye RX504 User Guide Page 2 5. User manual 6. Hard disk recommendation list 7. Warranty card 8. Registration card 9. R-E220 mobile data modem (optional) 10. Wireless LAN adaptor (optional) 11. Vibration bracket (optional) 4. Front panel description 1. REC LED: On when recording 2.
TeleEye RX504 User Guide Page 3 Section 2 Installation 1. Install Hard Disk 1. Remove left cover screw 2. Turn the left cover over 3. Slide the HDD into the slot. Take care for the hard disk pins, make sure all pins be...
TeleEye RX504 User Guide Page 4 4. Screw the HDD screws with provided screws and rings. 5. Restore and screw up the left cover 2. Remove Hard Disk 1. Remove left cover screw as shown in following figure 2. Turn the left cover over as shown in the following figure...
Page 5 3. Remove HDD screws 4. Slide the Hard disk out 3. Mobile data modem installation 1. Stick provided Velcro to R-E220 and RX504’ s rear panel, then stick together as following figure: Rear side of R-E220 Velcro position...
Measure the position of the mounting screws and drill holes on the mounting surface Screw up the screws on the mounting surface 2. Vertical mount Remove four side mounting screws on RX504 as shown follow Left mounting plate Right mounting plate...
Page 10
Left mounting plate iii. Rotate to RX504 front panel face down and screw up the side mounting screw to RX504 Measure the position of the mounting screws and drill holes on the mounting surface Screw up the screws on the mounting surface...
RS-485 bus For fix cameras, connect cameras to video inputs using RG59 cable. For PTZ cameras, connect camera’ s video output to RX504’ s video input using RG59 cable, and connect RS-485 to RX504’ s RS-485 out. 7. Alarm installation TeleEye RX supports up to 16 alarm ports in that order with tamper detection for connecting with alarm sensors, 4 additional input sensors and 4 relay ports for control.
Be sure to connect the Ground first Connect to ground Connect RX504 Ground terminal to car ground. Connect RX504 +12 V terminal to the +12 V power terminal which is energized in the accessory position of the ignition key.
1. Prepare a Laptop with COM port which running Windows XP 2. Install provided TeleEye WX-30 software 3. Power up RX504 4. Connect RX504 to PC by using provided NULL modem cable 5. Run TeleEye WX-30 6. Click Connections > Connect 7.
TeleEye RX504 User Guide Page 11 Click [Format Disk] to start format the Hard Disk. RX504 will need to restart after Hard Disk format. 3. Hard Disk available event Hard Disk available event triggers when any HDD failure or HDD changes happen. It is recommended to enable this event after format Hard Disk.
4. Network setup 1. Click Transmitter > Settings 2. Click Connection 3. Throughput setting is used to limit RX504’ s output data rate at individual video stream. 4. Select 100Mbps for LAN stream 5. Narrowband throughput, following are suggested initial throughput for reference only.
TeleEye RX504 User Guide Page 13 7. Set IP, port, subnet mask and gateway 8. DNS must be enabled for mobile connection, please enter valid DNS addresses. 5. Mobile data modem setup Make sure the mobile service provider support streaming at Internet connection.
Page 17
3. Click enable 4. Set dialup mode: Start up and SMS / Event In SMS / Event mode, RX504 will dial up to Internet only when event trigger a dialback action or receive a valid dialback SMS message. This mode is recommended to user who do not has real IP for mobile network connection Startup mode will dial up to Internet when RX504 power up.
Click OK Send SMS to the SIM card’ s number using the following format: teip<space><dialback ip><space><port><space>endip e.g. teip 202.73.90.90 2048 endip RX504 will dialback to the given IP once received the SMS. 2. Startup mode Run TeleEye WX-30 Click connect...
TeleEye RX504 User Guide Page 16 Enter sureLINK address or IP address Select TCP/IP Narrowband Enter password Click Connect 2. Live operation through LAN / wireless LAN 1. Run TeleEye WX-30 2. Click connect 3. type sureLINK address or IP address 4.
TeleEye RX504 User Guide Page 17 3. Recording Manual Recording Procedure : Step 1 : Click [Record] icon on the main panel as shown follow. Step 2 : Enter the administrator password. Step 3 : {RX Recording} panel pop up. Click the checkbox to select the camera for recording.
TeleEye RX504 User Guide Page 18 4. Video extraction Extract footage for back up purpose. This function can back up the data stored in the transmitter into local hard disk. User only need to select the amount of memory and starting time for back up and the function will calculate the end time automatically.
Page 22
TeleEye RX504 User Guide Page 19 Step 6: Select mode for footage extraction. Note: Lower frame rate for quick mode. Step 7 : Input Start Date / Time and Period Length / Footage Size in the boxes provided. (Note(Optional): 1. Click [Recording...
10. Customer shall be responsible for backing up the data contained in the disk products. 11. TeleEye shall have no responsibility arising out of any damage to, or loss of the data contained in the disk products.
IP address may change periodically (in case when dynamic IP is used), you do not need to worry about the expiration of the IP address. The sureLINK address can also be used in TeleEye RX web browsing to see live video on standard web browser (e.g. IE, Netscape).
Page 25
TeleEye RX504 User Guide Page 22 How to Apply for sureLINK Address You can apply for sureLINK by visiting our web site at http://www.TeleEye.com Step Step 1 Sign up to create your user account Login the page using your registered name and password.
Page 26
Registration Code in the fields provided respectively. Then click the Apply button. The process is then completed. After we receive your domain name registration for your TeleEye RX, your application will be processed. Normally, it requires about 2 to 3 working days to activate sureLINK for your TeleEye RX.
Page 27
TeleEye RX504 User Guide Page 24 Step 2 Enter the Old Registration Code, New Transmitter Serial Number and New Registration Code at each field provided. Click Modify button to submit the form. Step 4 Step 3 If the above procedure is completed successfully, the sureLINK will be effective immediately.
Appendix 4 Security Mode On RX504, there are 2 security modes: BASIC and ADVANCED. User can either choose BASIC security mode for simple usage or ADVANCED security mode for multiple user accounts and flexible access right. The comparison of the security modes can be found in the...
Page 30
TeleEye RX504 User Guide Page 27 Basic security mode -- User account ADMINISTRATOR Type Default Remark User name ADMINISTRATOR FIXED Access right Operation and System setting FIXED Network password 000000 Available to change USER Type Default Remark User name USER...
Page 31
TeleEye RX504 User Guide Page 28 Administrator account: ADMINISTRATOR** Type Default Remark User name ADMINISTRATOR FIXED Account type BOTH FIXED Access right FIXED Network password 000000 Available to change Local password 111111 Available to change Local time out 15 MINS...
Page 32
TeleEye RX504 User Guide Page 29 Advanced security mode -- Access right Group Features Involved VIDEO MONITORING basic video monitoring with fixed cameras browsing the event status** AUDIO MONITORING audio monitoring** and PA PA with microphone, PA with pre-recorded voice clips...
TeleEye RX504 User Guide Page 30 Appendix 5 Specification MODEL RX504 VIDEO INPUT (P): PAL/CCIR, 625 lines, 25 frames per second STANDARD (N): NTSC/EIA, 525 lines, 30 frames per second composite video, 1 Vp-p, BNC NO. OF CHANNELS VIDEO OUTPUT...
Page 34
TeleEye RX504 User Guide Page 31 RELAY SWITCH NO. OF CHANNELS MAX. RATING 24V AC, 1000mA POWER VOLTAGE 10-24V DC (12V typical) MAX. RATING OPERATING ENVIRONMENT AMBIENT TEMPERATURE 5°C - 40°C RELATIVE HUMIDITY < 85% (no condensation) MECHANICAL DESIGN DIMENSION...