Available DIP switch settings (Serial Interface)
The following table shows all the possible settings for the DIP switch. The
factory default settings are ON for switches 1 through 7 and OFF for switches
8 through 10.
Switch
1
2
3
4
5
6
7
8
9
10
Baud Rate
1200BPS
2400BPS
4800BPS
9600BPS
Command Emulation
Star mode
ESC/POS (TM-295)
ESC/POS (TM-290)
Not used (*1)
*1: Never set switch 7 to OFF at the same time that switch 8 is set to ON.
Parameter
Baud Rate
Data Length
Parity Check
Parity
Handshake
Command Emulation
Pin 6 (DSR) Reset Signal
Pin 25 (INIT) Reset Signal
ON
See table below.
8 bits
Disabled
Odd
DTR/DSR
See table below.
Enabled
Enabled
Switch 1
OFF
ON
OFF
ON
Switch 7
ON
ON
OFF
OFF
OFF
7 bits
Enabled
Even
XON/XOFF
Disabled
Disabled
Switch 2
OFF
OFF
ON
ON
Switch 8
ON
OFF
OFF
ON