IBM 8302 Hardware Maintenance Manual page 117

Ibm computer hardware user manual
Hide thumbs Also See for 8302:
Table of Contents

Advertisement

POST Error Code
111
I/O channel parity error
114
Adapter ROM error
129
Internal cache test error
135 Fan failure
151
System board failure
161
Bad CMOS battery
162
Configuration mismatch
163
Date and Time Incorrect
164
Memory Size Error
166
Boot Block Check Sum Error
167
No Processor BIOS Update Found
FRU/Action
1. Reseat adapters
2. Any adapter
3. Riser card
4. System Board
1. Adapter Memory
2. System Board
3. Riser card
1. Processor
2. L2 Cache Memory
3. System Board
1. Fan
2. System board
1. System Board
1. Run Setup
2. CMOS Backup Battery (see "Safety
information" on page 271)
3. System Board
1. Run Setup and verify Configuration
2. Had a device been added, removed,
changed location? If not, suspect that
device.
3. Power-on external devices first, then
power-on computer
4. CMOS Backup Battery (see "Safety
information" on page 271)
System Board
5. System Board
1. Time and Date Set
2. CMOS Backup Battery (see "Safety
information" on page 271)
3. System Board
1. Run Setup. Check System Summary
menu for memory size change. (See
"Setup Utility program" on page 24.)
2. Run the Extended Memory Diagnostic
tests
1. Run Flash Recovery using Boot Block.
See "Flash recovery boot block jumper"
on page 267.
2. System Board
1. Run Setup. Check Stepping level for
the BIOS level needed, then perform
the flash update.
2. Processor
Chapter 7. Symptom-to-FRU Index
111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents